Installation Mode: | 19” Rack | Input Voltage: | AC220V |
---|---|---|---|
Power Factor: | 0.99 | Input Frequency: | 45~65Hz |
Application: | Outdoor Telecom Cabinet | Max Output Current: | 150A |
High Light: | telecom rectifier module,dc rectifier system |
150A Small Scale Program Telecom Rectifier System With Perfect Battery Management
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | Input Voltage: AC220V |
Brand Name: ESTEL | Output Voltage: DC48V |
Model Number: GPE48150 | Max Output Current: 150A |
Product Name: Telecom Rectifier System | Input Frequency: 45~65Hz |
Certification: ISO9001, CE, 3C, FCC, TLC | Max. Input Current: 60A |
Installation Mode: 19” rack | Power Factor: 0.99 |
Application: outdoor telecom cabinet |
Components: 5×30A rectifier module, 1×monitoring module, power distribution |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union |
Supply Ability: | 20,000 sets per month |
Delivery Time: | 7-10 working days |
Packaging Details: | carton/wooden case |
GPE48150 consists of two layers of 1U insert frame. The first layer consists of rectifier module (at least 1 set, up to 2 sets) and 1monitoring module . The second layer frame consists of rectifier module, and can be up to 3 sets. The second layer is optional, depending on the customer. The configuration is optional, as following table:
Configuration | Rectifier Module | Monitoring Module | Power Distribution |
Standard | GPR4830A R01 |
GPM48VI
|
Load output 1 way |
AC power (single-phase or three-phase) get into the rectifier module through the AC input terminal (L1, L2, L3, N). OUT+, OUT- is DC power system output terminal. User load and the battery access to the power system DC output terminal through the power-down contactor. load power-down contactor is normally closed under situation of no trigger, battery power-down contactor is normally open under situation of no trigger.
In normal conditions, various parameters of rectifier module and power distribution units are controlled by the monitoring module, and work according to the predetermined parameters or user commands. If there is a power failure, at this time system will be powered by battery, with the discharge of the battery, battery terminal voltage begin to decline, when the battery voltage is lower than 46.2V (adjustable), the monitoring module reports DC undervoltage alarm signal, when the battery voltage drops to 45.6V (adjustable), the monitoring module controls the load power-down contactor, turning off the load power supply. When the external power recovery, the system will restore the normal working state of the battery and the load (the above monitoring data is the system default value, the user can re set).
Input | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Input voltage range | 90 | 220 | 280 | Vac | |
Input frequency | 45 | 50 | 65 | Hz | |
Input current | 60 | A | |||
Power factor | 0.99 | Rated input, full load output |
Output | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Output voltage range | 42 | 53.5 | 58 | Vdc | |
Output current range | 0 | 150 | A | 176~280VAC | |
0 | 75 | A | 90~175VAC | ||
Single module current limit point | 31 | 33 | 35 | A | System current limit point = Single module current limit point* module quantity |
Ripple (Vp-p) | 200 | mv | At rated input/output, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz. | ||
Output efficiency | 88 | 90 | % | 220Vac input, output 120A | |
83 | 85 | % | 110Vac input, output 60A | ||
Regulation | ±2 | % | |||
Load regulation | ±2 | % | |||
Line regulation | ±1 | % |
Insulation rating | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Input-chassis | 2121 | Vdc | |||
Input - output | 4242 | Vdc | |||
Output - chassis | 710 | Vdc | |||
Insulation resistance | At normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ |
Ambient requirements | |||||
Parameters | Min. | Typical | Max. | Unit | Remark |
Operating temp | -25 | 55 | °C | When ≥55°C, derating output | |
Storage tempStorage temperature | -40 | 80 | °C | ||
Relative humidity | 10 | 90 | % | no condensing | |
Atmospheric pressure | 70 | 106 | KPa | ||
Altitude | 0 | 3000 | m | ||
Cooling method | Forced cooling with fan |
Mechanical specifications | |
Dimensions (mm) | 482.6mm×304mm×87.3mm |
Weight (kg) |
≤11kg (Inclusive of module) ≤5.175kg (Frame + Distribution, exclusive of module) |
Chassis connects with external electric through system interface board. As shown in figure below:
Wiring Terminal Instruction:
AC input port is used for connecting AC input.
5. Application
(1) Small scale program controlled exchangers
(2) Access network
(3) Transmission equipment
(4) Mobile communication
(5) Satellite communication ground station
(6) Microwave communication
6. Features
(1) Adoption of active power factor compensation technology with factor >0.99
(2) Wide operating range of AC input voltage: 90~280Vac
(3) Operating temperature range: -25°C~+55°C
(4) Zero current/voltage switching tech with high efficiency ≥88%
(5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.
(6) Hot-swappable
(7) Input over/under voltage protection
(8) Output over voltage protection
(9) Output over current protection
(10) Output short circuit protection
(11) Auto current sharing, parallel output
(12) Embedded mounting
7. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
8. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Contact Person: Fiona Liang
Tel: +8613752765943 / 86-0755 23592644