Product Details:
Payment & Shipping Terms:
|
Input Rating: | AC380V 3ph Wye250A Max. | Number Of Phase / Wire: | AC380V 3ph Wye250A Max. |
---|---|---|---|
Current THD: | <5% | Output Power: | 150kW (2gun) |
Output Voltage Range: | DC200V-1000V | Rated Output Current: | 200A*2 |
Highlight: | EV 150KW DC Fast Charger,380V Type 2 EV Charging Station,Type 2 EV Charging Station With OCPP |
1. Technical Parameters
The manufacturer is not liable for damages, losses, costs or expenses incurred
by any user of the EVSE (e.g. the installation engineer or owner of the EVSE) if
such damages, losses, costs or expenses result from a failure to comply with the applicable safety instructions given by the manufacturer, including, but not limited to, the following:
• Power outages or disruptions to the electrical supply to the EVSE.
• Accumulation of dirt or ingress of foreign substances within the EVSE.
• Corrosion of component parts.
• Upgrades enhancements or modifications to the equipment or its use.
• Damage to software or hardware due to any IT security problem, such as but not limited to a virus breakout or malicious hacking of the system.
• Damage or failure of equipment caused by vermin, insect infestations or the like.
• Damage or failure resulting from faults in some other equipment connected to
the scope of work.
• Damage or loss caused by hazards such as fire, flood, storm or the like or
spillage or leakage of chemicals or harmful substances onto the EVSE.
• Fault tracing caused by problems from a source external to the scope of work.
• Unprofessional or incorrect installation, installation not complying to standards, or installation not following the installation instructions contained in the product specific manual.
• Improper operation (in breach of the technical requirements or specifications or manuals of the product), negligence or repairs carried out by the Owner (or any third party not authorized by TCHARGE).
• Non-compliance with the applicable safety regulations or other legal standards by other parties than TCHARGE.
• Insufficient ventilation of the EVSE.
• Operation of the EVSE outside of its design conditions.
• Relocation of the EVSE from the original installation location or alteration of the overall system design.
• Only make changes to the EVSE if the manufacturer approves in writing of the changes.
2.Specification
Item Number | E3P-150K-D2-200A-EU01 | |
Power input |
Input rating | AC380V 3ph Wye250A max. |
Number of phase / wire | 3ph / L1, L2, L3, N, PE | |
Power factor | >0.98 | |
Current THD | <5% | |
Efficiency | >95% | |
Power output |
Output power | 150kW (2gun) |
Output voltage range | DC200V-1000V | |
Rated output current | 200A*2 | |
Output accuracy | <0.5% (voltage and current) | |
Protection | Protection | Over current, Under voltage, Over voltage, Residual current, Surge protection, Short circuit, Over temperature, Ground fault |
User interface & control | Display | 10” touch screen |
Support language | English (Other languages available upon request) | |
Charge option | Charge options to be provided upon request: Charge by duration, Charge by energy, Charge by fee | |
Environmental | Operating temperature | minus 20 ℃to+55℃ (derating when over 55℃) |
Storage temperature | -40 ℃to+70℃ | |
Humidity | < 95% relative humidity, non-condensing | |
Altitude | Up to 2000 m (6000 feet) | |
Mechanical | Ingress protection | IP54 |
Enclosure Protection against External Mechanical Impacts | IK10 according to IEC 62262 | |
Cooling | Air forced | |
Charging cable length | 5m | |
Dimension (W*D*H) mm | 700*780*1720mm | |
Weight | 300kg |
3. Dimension Diagram
4. installation condition
1.The charger should be installed on a flat concrete foundation, with a cable entrance reserved.
2.The vertical inclination is less than 5%.
3.Fix the bottom of the charger by eight M8 screws embedded in the foundation.
4.Keep at least 100cm spacing around the charger for heat dissipation and operation
5.An Awning is recommended.
5. DC Charging Station Details
5. Projoct Case Show
6. Make sure that the power supply to the EVSE is disconnected.
• Other Task is to be performed by qualified personnel.
• Keep unauthorized personnel at a safe distance during cleaning or maintenance.
• Put on the correct personal protective equipment.
Maintenance schedule for the owner
Task | Frequency | Procedure |
Clean the cabinet. | 4 months | |
Do a check for damage on the EV charge cables and the connectors. | 3 months | |
Do a check for damage on the cabinet. |
6 months
|
|
Replace the air inlet filters. | 1 year | |
Make sure that the manufacturer does maintenance on the EVSE. | 1 year | |
Replace the air outlet fil ters. |
After the first year, then 2 years |
7.Packing
Contact Person: Ms. Fiona Liang
Tel: +8613752765943 / 86-0755 23592644