Product Details:
Payment & Shipping Terms:
|
Installation Mode: | 19” Rack | Input Voltage: | AC220V |
---|---|---|---|
Power Factor: | 0.99 | Input Frequency: | 45~65Hz |
Application: | Outdoor Telecom Cabinet | Output Power: | 4800W |
Highlight: | dc rectifier system,rack mount rectifier |
90A Outdoor Cabinet Telecom Rectifier System , DC Rectifier System With Output Short Circuit Protection
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | Input Voltage: AC220V |
Brand Name: ESTEL | Output Voltage: DC48V |
Model Number: GPE4890J | Output Power: 4800W |
Product Name: Telecom Rectifier System | Input Frequency: 45~65Hz |
Certification: ISO9001, CE, 3C, FCC, TLC | Input Current: 42A |
Installation Mode: 19” | Power Factor: 0.99 |
Application: outdoor telecom cabinet |
Components: 3×30A rectifier module, 1×monitoring module, power distribution |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, , T/T, Western Union |
Supply Ability: | 20,000 sets per month |
Delivery Time: | 7-10 working days |
Packaging Details: | carton/wooden case |
1. GPE4890J System Configuration
GPE4890J consists of distribution unit, rectifier module (up to 3 sets) and 1 monitoring module. The configuration is optional, as following table:
Configuration | Rectifier Module | Monitoring Module | Power Distribution | Remark |
Standard | GPR4830 | GPM48VI (With Ethernet Port) |
4P output terminal (1×anode, 1×LVLD cathode, 1×LVBD cathode, 1×battery cathode ).
|
For details, please refer to the specifications of modules. |
Optional 1 | GPR4830 | |||
Optional 2 | GPR4815 | |||
Optional 3 | GPR4820 |
2. GPE4890J Working Principle
After AC power is controlled by the AC hydraulic switch and then through the EMI board lightning protection and filtering processing, into the rectifier module, AC hydraulic switch has the function of overload and short circuit protection to AC power.
Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under -46.2V±0.5V, the monitoring module reports battery under voltage alarm signal; When the battery voltage is under -45.6V±0.5V, close LVLD load output; When the battery voltage is under -43.2V±0.5V, close LVBD load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).
3. GPE4890J System Properties
Input | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Input voltage range | 90 | 220 | 280 | Vac | Nominal operating voltage range 100V-240V |
128 | 280 | 396 | Vdc | Support DC input | |
Input frequency | 45 | 50 | 65 | Hz | AC input |
Start inrush current | 42 | A | When 25°C Cold start, 280Vac input, full load test | ||
Power factor | 0.99 |
Output | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Output voltage setting | -53.5 | Vdc | |||
Output voltage range | -43.2 | -53.5 | -57.6 | Vdc | |
Output current range | 0 | 90 | A | 176~280VAC/176-396Vdc input | |
0 | 45 | A | 90-<176Vac/128~<176Vdc input | ||
Ripple (Vp-p) | 200 | mv | At low temperature operating for 1 hour, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, 20MHz frequency band 20cm twisted pair. | ||
Output efficiency | 91 | % | 220Vac/280Vdc input,rated output | ||
85 | % | 110Vac/200Vdc input, 33A output | |||
Regulation | ±2 | % | |||
Load regulation | ±2 | % | |||
Voltage regulation | ±1 | % | |||
Output power | 4800 | W | 176-285Vac/176-396Vdc input | ||
2400 | W | 90-<176Vac/128~<176Vdc input (configure GPR4830A1) |
Insulation rating | ||
Parameter | Min | Remark |
Input - output | 3535Vdc/10mA//1min | No fly arc, no breakdown. Before the test, all the lightning protection and surge protection devices shall be cut off from the test points, and any rectifier module and monitoring unit should not be installed. |
Input-chassis | 3535Vdc/10mA//1min | |
Output - chassis | 1414Vdc/10mA//1min | |
Insulation resistance | At normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ |
Ambient requirements | |||||
Parameters | Min. | Typical | Max. | Unit | Remark |
Operating temp | -20 | 55 | °C | ≥ 55°C, output with derating power | |
Storage tempStorage temperature | -40 | 80 | °C | ||
Humidity | 10 | 90 | % | Relative humidity, no condensing | |
Atmospheric pressure | 70 | 106 | KPa | ||
Altitude | 0 | 3000 | m | ||
Cooling method | Forced cooling with fan | ||||
Ingress protection | The unit can operate when the diameter of dust particle is more than 5µm, with density ≤3*104 /m3. The dust shall not be conducting, electromagnetic or corrosive. The product don’t have waterproof function. |
Mechanical specifications | |
Dimensions (Overall) | 482.6mm×265mm×88.1mm |
Weight(kg) (Overall) |
≤11kg (Inclusive of module) ≤5.175kg (Frame + Distribution, exclusive of module) |
4. Application
(1) Small scale program controlled exchanger
(2) Access network
(3) Transmission equipment
(4) Mobile communication
(5) Satellite communication ground station
(6) Microwave communication
(1) Adoption of active power factor compensation technology with factor >0.99
(2) Wide operating range of AC input voltage: 90~280Vac
(3) Operating temperature range: -25°C~+55°C
(4) Zero current/voltage switching tech with high efficiency ≥91%
(5) Perfect battery management, charge & discharge management, battery temperature compensation, low voltage protection, extend battery lifetime
(6) Hot-swappable
(7) The monitor has sleeping function, saving energy.
(8) Input over/under voltage protection
(9) Output over voltage protection
(10) Output over current protection
(11) Output short circuit protection
(12) Embedded mounted
Chassis connects with external electric through system interface board. As shown in figure below:
Wiring terminal Connection Instruction:
SPD: lightning arrester; L: live line; N: neutral line; transfer switch: lithium battery and lead acid battery transfer switch,switch to I - lithium battery; O - lead acid battery;
Signal input output terminal definition as the right:
FU1: battery fuse; LOADF: load fuse; 12V-12V power supply; SPD: lightning arrester signal;1-4: dry contact output.
Output terminal definition as the right:
BAT-: battery cathode; LOAD2-: LVBD cathode; LOAD1-: LVLD cathode; +: Load and battery cathode
7. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
8. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Contact Person: Fiona Liang
Tel: +8613752765943 / 86-0755 23592644