Product Details:
Payment & Shipping Terms:
|
Name: | Rack Mount Telecom Rectifier | Model: | EVCSE48200 |
---|---|---|---|
Controller: | Ethernet , SNMP, ModBus And RS485 Communication | Installation Mode: | 19 Inch Rack |
Full Capacity: | 23.2KW | Output Voltage: | -48VDC (-42 To -58VDC) |
Module: | Hot-swappable | Battery Management: | Support |
High Light: | 220Vac 19-Inch Rectifier,Hot-swappable Module 19-Inch Rectifier,23.2KW Power Supply System |
1. Telecom Power System Details:
Place of Origin: Shenzhen, China (Mainland) | Single phase 220Vac |
Brand Name: ESTEL | 48V( 40~58Vdc adjustable) |
Model Number: EVCSE48200 | Output Power: 23.2KW |
Product Name:AC/DC Power System | Input Frequency:50/60Hz±10% |
Certification: ISO9001, CE, 3C, FCC, TLC | Output Current:50-400A |
Application: transmission device,Satellite communication ground station | Power Factor: ≥0.99 |
Weight: 15kgs | Current sharing at paralleling: ≤±3% |
Battery Input: 100A*2 | Voltage stability precision: ≤±0.6% |
Load Output: (10-63)A*10 | Efficiency: ≥91% |
2. Rectifier System Description
The EVCSE48400 consists of VSM-B control module, VRM48 rectifier module, and etc. And there is AC-DC distribution unit. It’s capacity can reach 48V/50A~400A combining racks with rectifiers.
1) The rectifier module adopts active power factor compensation technology, and the power factor value reaches 0.99.
2) The normal working range of AC input voltage is wide to 90~290V, Single Phase, (323V~480V ac, 3 Phase).
3) The rectifier module adopts full-bridge soft-switching technology, and the efficiency is up to 96%.
4) Smart battery management. There are load power-off and battery low-voltage protection (LVLD+LVBD) and secondary power-off (secondary power switch) functions, which can realize functions such as temperature compensation, automatic equalization and floating charge control, automatic voltage regulation, battery capacity calculation, and online battery testing.
5) The rectifier module adopts non-damage hot-swappable technology, plug and play, and the replacement time is less than 1min.
6) Networked design, providing multiple communication interfaces (such as RS485, dry contact), flexible networking, real-limited local and remote monitoring, unattended.
7) Lightning protection design for AC and DC sides, suitable for thunderstorm areas.
8) Support fault protection and fault alarm functions.
9) Friendly operation and maintenance can be installed against the wall, effectively saving space.
10) Ultra low radiation. Adopt advanced electromagnetic compatibility design.
3. Rectifier Control ModuleTechnical Parameters
Input | |
Rated volage | Single phase 220Vac |
Operation voltage range | 90~300Vac |
Current | ≤18.5A |
Frequency | 50/60Hz±10% |
Power factor | ≥0.99 |
Output | |
Voltage | 48V( 40~58Vdc adjustable) |
Current | 50A@58 |
Current sharing at paralleling | ≤±3% |
Voltage stability precision | ≤±0.6% |
Protection | Over voltage, over current, output short-circuit and over temperature |
Other data | |
Efficiency | ≥92% |
Cooling mode | Fan cooling |
Operating temperature | -10~+55℃ |
Degree of protection class | IP20 |
Ripple voltage | ≤200mVpp |
Phosphometric noise | ≤2mVrms |
Load effect | ≤±0.5% |
Restoring time of load effect | ≤200μs |
Source effect | ≤±0.1% |
Dimension (mm) | 106(W) ×218(D) ×83.8(H) |
Weight | 2.2kg |
EMC | |
Emission | Ac input in accordance with EN50081-1 and EN50081-2; DC output in accordance with EN50081-2 |
Immunity | In accordance with EN50081-1, EN50081-2 |
Safety | In accordance with IEC950, EN60950, EN41003, UL1950, AS/NZ3260 |
3. Model EVCSE48400 Operating Principle
Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under 42V±0.5V, the monitoring module reports battery under voltage alarm signal and cuts off the load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).
4. Rectifier Application
(1) Integration access
(2) Indoor distribution and extension system
(3) Mobile station and extension coverage system
(4) WLAN
(5) Satellite communication ground station and microwave communication station
(6) Weak current distribution room
(7) Other AC/DC uninterruptible power system
5. Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
6. Product Pictures:
Contact Person: Ms. Fiona Liang
Tel: +8613752765943 / 86-0755 23592644