Product Details:
Payment & Shipping Terms:
|
Input Voltage: | 140~300VAC | Application: | Industrial Device |
---|---|---|---|
Input Frequency: | 47~63Hz | Max. Output Current: | 8A |
Output Efficiency: | Natural Cooling | Output Voltage: | DC52V |
High Light: | industrial power supply,server power supply |
Enclosed Industrial Power Supplies With Short Circuit / Overvoltage Protections
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | Input Voltage: 140~300VAC |
Brand Name: ESTEL | Output Voltage: DC52V |
Model Number: GPAD401M52-1A | Output Power: 400W |
Product Name: Industrial Power Supplies | Input Frequency: 47~63Hz |
Certification: ISO9001, CE, 3C, FCC, TLC | Max. Output Current: 8A |
Application: Industrial Device |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union |
Supply Ability: | 20,000 sets per month |
Delivery Time: | 7-10 working days |
Packaging Details: | carton/wooden case |
1. Description
The GPAD401M52-1A industrial power supply is with wide input voltage range (140 to 300Vac), with single way output. The power system is equipped with protections against output short-circuit, over-current and output over-voltage. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technology.
2. Specifications
Technical Parameters
Ambient conditions | |||||
Parameters | Min | Typical | Max | Unit | Note |
Operating temperature | -40 | +55 | °C | ||
Storage temperature | -45 | +85 | °C | ||
Relative humidity | 10 | 90 | % | ||
Altitude | 3000 | m | |||
Atmospheric pressure | 70 | 106 | KPa | ||
Cooling | Natural cooling |
Input | |||||
Parameter | Min | Typical | Max | Unit | Note |
AC input voltage range | 140 | 220 | 300 | Vac | |
AC input start voltage | 155 | 285 | Vac | ||
AC input frequency range | 47 | 50 | 63 | Hz |
Basic output characteristics | |||||
Parameter | Min | Typical | Max | Unit | Note |
Output voltage range | +52 | Vdc | |||
Output voltage range | 51.2 | 52.8 | Vdc | ||
Output current range | 0 | 8 | A | ||
Load regulation | ±1.5 | % | |||
Stabilized voltage precision | ±1 | % | |||
Line regulation | ±0.5 | % | |||
Noise +ripple (peak to peak value) | 80 | mV | At rated input/output, apply 0.1uF film capacitor and 10uF/50V HF electrolyte capacitor, oscilloscope band width of 20MHz. | ||
Output power | 400 | W | Natural cooling/full load output | ||
Output efficiency | 87 | % | Rated input/output | ||
Temperature coefficient | ±0.02 | %/°C | |||
Recovery time of load effect | 200 | uS | Load mutation, overshoot of output voltage rating of plus or minus 5% or less. | ||
Turn on/off overshoot | ±5 | % |
Protection | |||||
Parameter | Min | Typical | Max | Unit | Note |
Input over-voltage protection | 310 | 320 | Vac | With 10% load | |
Input under-voltage protection | 120 | 130 | Vac | ||
Output over-voltage protection | 60 | V | |||
Output current-limited protection | 9 | 12.75 | A | Self-recovery | |
Over temperature protection | 95 | 105 | °C | Self-recovery | |
Output short-circuit protection | Can be long time short-circuit and self-recovery |
EMC and others | |
Parameter | Standard and requirements |
Radiation emission(CE) | EN55022 - Class B |
Conduction interference(RE) | EN55022 - Class B |
Surge | EN61000-4-5 LEVEL 3 , line-line 2KV, line-earth 4KV |
Atmosphere discharge (ESD) | EN61000-4-2 LEVEL 3 (Criterion B) |
Contact discharge(ESD) | EN61000-4-2 After the shell is mounted, the discharge of the shell of the machine box does not affect the work of the power module. Contact discharge: ±6KV; Air discharge:±8KV (criterion B) |
Radiated anti-interference (RS) | EN61000-4-3 LEVEL 2: 3V/m Field strength |
Conducted anti-interference (CS) | EN61000-4-6 LEVEL 2: 3V/m Field strength |
Electrical Fast Transient(EFT) | IEC61000-4-4 LEVEL 3: 2KV |
Voltage dips and short interruptions | EN61000-4-11 drop to 70%, 40%, 0%; duration time is 10ms, 100ms, 1000ms etc |
Vibration | 5 ~ 9 Hz, the amplitude is 3.5 mm; 9 ~ 200 Hz, acceleration is 10 m/s2; three axial, Sweep frequency vibration 5 times in each direction (3 * 50 minutes), the power supply is not damaged. |
Shock | A half sine wave, the acceleration is 20 G, pulse width is 11 ms, shock axis: 3 direction X, Y, Z, shock times: 3 times in each direction. |
Collision test | Collision waveform: half sine wave; peak acceleration: 180m/s2; pulse width: 6ms; collision direction: 6 direction; collision frequency: 100 times in each direction. |
Hydrostatic pressure test |
TL=Wt×(S-1)×F×9.8(N) Wherein: TL: applied pressure values, the unit is N; Wt: the weight of the package itself, the unit is kg; S: Allowable stacking layers numeber , select the maximum stacking layers number; F: safety coefficient, is usually 5; holding time for applying pressure is 2h. |
Moisture proof | GB/T2423.4-1993 alternating damp heat test, 24~45°C, 95%RH, 48h |
Anti-fungal | GB/T2423.16-1999 fungus test, level 2 |
Cooling | Module naturally conduct and dissipate heat |
Noise | Within the scope of the input voltage and output voltage and current, at a distance 1 meter from front, back, left, right of power supply, , at a distance 1.5 meter from upper and lower of power supply, power supply noise is less than 55 DB (A) |
MTBF | MTBF≥100,000h |
Annual return rate | ≤1% |
Smelling | Any abnormal and poisonous smelling is not allowed |
Dust proof | Have certain dust function |
Safety and insulation grade | ||
Parameter | Requirement | Note |
Input –output | 1500Vac/10mA//1min | No arc, no breakdown, put off discharge tube when testing |
Input –earth | 1500Vac/10mA//1min | |
Output –earth | 500Vdc/10mA//1min | |
Ground resistance | <0.1Ω | |
Insulation resistance | ≥10MΩ | In normal atmospheric pressure, when relative humidity is 90%, testing voltage is 500VDC, the insulating resistance of input-output, input-grounding, output-grounding are all ≥10MΩ |
Contact current | <1.75mA | For a single power supply, contact current < 1.75 mA |
Ground resistance | <0.1Ω | For a single power supply, Ground resistance <0.1Ω. |
Mechanical specifications | |
L×W×H (mm) | As below figure |
Weight(kg) | ≤0.9Kg |
3. Alarm
Alarm signal | |||
Items | Yes / no | Technical indication | Notes |
Power down alarm signal | Yes |
When normal input, output low impedance; When the power off, output high impedance |
AC input fails, output +52V, in the case of full load, alarm signal is up to + 2.2 V (test need to add pull resistance); when +52V drop to +38 V, time interval shall not be less than 1 ms |
Normal input LED display | Yes | Using indicator light(red): red light is on, input is normal | |
Normal output LED display | Yes | Using indicator light(green): green light is on, output normal 52V | |
Output on/off control | Yes | Output switch controller controls internal power supply protection circuit signal electric potential by rocker switch on the panel to achieve output power off and on. |
Note:
1. The power indicator light is required to install on the PCB board ( in the same side of the input and output socket), the red light on the input, the green light on the output.
2. Alarm port circuit requirements: when input power is normal, optocoupler conduction (saturation), alarm port output low impedance . When input power is down, Optocoupler cutoff, IN OK port output high impedance, and the driving current of alarm port need reach 10mA.
4. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
5. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Contact Person: Fiona Liang
Tel: +8613752765943 / 86-0755 23592644