Product Details:
Payment & Shipping Terms:
|
Installation Mode: | 19” Rack | Power Factor: | 0.98 |
---|---|---|---|
Input Frequency: | 45~65Hz | Application: | Outdoor Telecom Cabinet |
Output Efficiency: | 92% | Input Voltage: | AC220V |
Highlight: | telecom rectifier module,dc rectifier system |
Professional Telecom Rectifier Module System DC48V Remote Monitoring
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | Input Voltage: AC220V |
Brand Name: ESTEL | Output Voltage: DC48V |
Model Number: GPE48150A | Output efficiency:92% |
Product Name: Telecom Rectifier System | Input Frequency 45~65Hz |
Certification: ISO9001, CE, 3C, FCC, TLC | Max. Input Current: 50A |
Installation Mode: 19”cabinet installed | Power Factor: 0.98 |
Application: outdoor telecom cabinet |
Components: 5×30A rectifier module, 1×monitoring module power distribution |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union |
Supply Ability: | 20,000 sets per month |
Delivery Time: | 7-10 working days |
Packaging Details: | carton/wooden case |
1. Application
(1) Small scale program controlled exchangers
(2) Access network
(3) Transmission equipment
(4) Mobile communication
(5) Satellite communication ground station
(6) Microwave communication
2. Features
(1) Adoption of active power factor compensation technology with factor >0.98
(2) Wide operating range of AC input voltage: 90~290Vac
(3) Operating temperature range: -25°C~+55°C
(4) Zero current/voltage switching tech with high efficiency ≥91%
(5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.
(6) Hot-swappable
(7) Input over/under voltage protection
(8) Output over voltage protection
(9) Output over current protection
(10) Output short circuit protection
(11) Auto current sharing, parallel output
(12) Embedded mounting
3. Description
The GPE48150A embedded power system consists of the power distribution frame, monitoring module and rectifier module. The whole system is of high reliability and performance, and can be operated through PC software.
GPE48150A consists of power distribution unit, rectifier module (from 1 set, up to 3 sets) and 1 monitoring module. The configuration is optional, as following table:
Configuration | Rectifier Module | Monitoring Module | Power Distribution | Remark |
Standard | GPR4830A | GPM48DI (With Ethernet Port) |
AC power distribution: single phase 3 wire input, main power 2 phase AC MCB (50A); DC power distribution: battery fuse 80A×1; LVLD: 40A×3 LVBD: 10A×1 |
For details, please refer to the specifications of modules. |
Optional 1 | GPR4810A | GPM48D (Without Ethernet Port) | ||
Optional 2 | GPR4815A | |||
Optional 3 | GPR4820A |
AC power is first input AC-INPUT MCB and then feed into the rectifier module after lightning proof and filtering. AC-INPUT acts as protection to over load and short circuit to AC power. LOAD1-, LOAD2-, LOAD3-, LOAD4- are connected with two load down contactor KM1, KM2. The user’s battery is connected to the DC output side through MCB BAT and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.
Under normal conditions, every parameter of rectifier modules and power distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains faults, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When battery voltage is under -47V±0.5V, the monitoring module sends DC under voltage alarm signal and when battery voltage is under -46.0V±0.5V (adjustable), the monitoring module will control the contactor KM1 to cut off LOAD3 and LOAD4 and retains power to LOAD1 and LOAD2 . If battery voltage drops to -43.0V±0.5V (adjustable), the monitoring module will control the contactor KM2 to cut off output of LOAD1 and LOAD2, then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).
Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding.
6. GPE48150A Properties
Input | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Input voltage range | 90 | 220 | 285 | Vac | |
Input frequency | 45 | 50 | 65 | Hz | |
Input current | 50 | A | |||
Power factor | 0.98 |
Output | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Output voltage range | 42 | 53.5 | 58 | Vdc | |
Output current range | 0 | 150 | A | 176~285VAC | |
0 | 75 | A | 90~175VAC | ||
Ripple (Vp-p) | 200 | mv | At rated input/output, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz. | ||
Output efficiency | 90 | 92 | % | 220Vac input | |
83 | 85 | % | 110Vac input | ||
Regulation | ±1 | % | |||
Load regulation | ±1 | % | |||
Line regulation | ±1 | % |
Insulation rating | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Input-chassis | 2121 | Vdc | |||
Input - output | 2121 | Vdc | |||
Output - chassis | 750 | Vdc | |||
Insulation resistance | At normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ |
Ambient requirements | |||||
Parameters | Min. | Typical | Max. | Unit | Remark |
Operating temp | -25 | 55 | °C | When ≥55°C, derating output | |
Storage tempStorage temperature | -40 | 80 | °C | ||
Relative humidity | 10 | 90 | % | no condensing | |
Atmospheric pressure | 70 | 106 | KPa | ||
Altitude | 0 | 3000 | m | ||
Cooling method | Forced cooling with fan |
Mechanical specifications | |
Dimensions (mm) | 482.6mm×255mm×130.5mm |
Weight (kg) |
≤11kg (Inclusive of module) ≤5.175kg (Frame + Distribution, exclusive of module) |
Chassis connects with external electric through system interface board. As shown in figure below:
Wiring Terminal Instruction:
8. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
9. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Contact Person: Fiona Liang
Tel: +8613752765943 / 86-0755 23592644