Product Details:
Payment & Shipping Terms:
|
Structure: | Double Wall, With Insulation, Sandwich Structure. | Coating: | Anti-corrosion Outdoor Powder Coating |
---|---|---|---|
External Size: | H×W×D1250×1200×650 | Applicaiton: | Outdoor Telecom Base Station |
Protection: | Dustproof, Sunproof And Rainproof | Doors: | 2 |
Cooling Capacity: | 1500W(air Conditioner) | ||
High Light: | BTS outdoor cabinet,outdoor data cabinet,Galvanized Steel Base Station Cabinet |
Base Station Street Cabinets Telecoms Galvanized Steel Material PEF Heat Insulation
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | External Size H×W×D1250×1200×650mm |
Brand Name: ESTEL |
Structure: double wall, with insulation, sandwich structure |
Model Number: DDTE046 |
Cabinet Layout: two compartments |
Product Name: Outdoor Integrated Telecom Cabinet |
Cabinet Lock: anti-theft three point lock |
Certification: ISO9001, CE, 3C, FCC, TLC, IP55 |
Protection Level: IP55 |
Application: outdoor telecom base station | Cable Entry: at cabinet bottom |
Material: galvanized steel | Illumination: DC48V LED lamp |
Heat Insulation: PEF |
Grounding Protection: copper bar |
Color: grey (support custom made) |
Cooling: AC220V Air Conditioner |
Coating: anti-corrosion outdoor powder coating |
Accessories Options: PDU, environment monitoring system |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: |
L/C,D/A,T/T, Western Union, Paypal, etc |
Supply Ability: | 6,000 sets per month |
Delivery Time: | 15-20 working days |
Packaging Details: | wooden case |
1. Technical Parameters
Item | Type | Technical Parameter |
Structure | Dimension | External Dimension H×W×D1250×1200×650mm |
Layout | Two compartments | |
Equipment Installation Method | 19” standard rack and battery shelf | |
Door |
With 1 front door, 1 back door, and 1 left door; and anti-theft three point lock for outdoor cabinet (support padlock) |
|
Material |
1.Galvanized steel; 2.Double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls. |
|
Structure | Assembled | |
Ingress Protection | IP55 | |
Temperature Control | Cooling | AC220V 1500W Air Conditioner |
Lighting | LED lamp | 48V LED lamp |
Temperature | Temperature | Working Temperature: -40°C ~ +55°C |
Storage Temperature: -50°C ~ + 70°C | ||
Transport Temperature: -50°C ~ +70°C | ||
Humidity | Relative Humidity | 5% ~ 100% |
Pressure | Air Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity | Solar Radiation Intensity | 1124 × (1±5%)W/m2 |
Accessories List
No. | Item (specs) | Quantity | Unit | Remark |
1 |
Cabinet 1250×1200×650(H×W×D) |
1 |
set |
Installation method: whole cabinet |
2 | AC compressor air conditioner, 1500W | 1 | set | |
3 | 2U Environment Monitoring Unit | 1 | set | |
4 |
Sensors (including 1 smoke sensor, 6 door alarms, 3 LED lights, 1 water sensor, 2 temperature and humidity sensor, 1 mains power failure sensor) |
1 |
set | |
5 |
PDU Grade B lightening arrestor 60KA×1; Circuit breaker: 63A/2P×1, 63A/1P×2, 32A/1P×2, 16A/1P×3; Maintenance socket ×1. |
1 |
unit |
|
6 | ETSI shelf | 1 | unit | |
7 | Air guide frame | 1 | set | |
8 | Fan tray | 1 | unit | |
9 | Mounting accessories | 1 | set | |
10 | Package | 1 | set |
2. Description
The cabinet includes two compartments. The left compartment is cable distribution compartment, the upper part of the right compartment is equipment compartment, and the lower part of the right compartment is battery compartment. The cabinet cooling uses 1500W AC air conditioner, to ensure the equipments and batteries operate normally at stable temperature range, so as to make the service life of the equipments and batteries much longer and their performance more stable.
2.1 Cabinet Door and Lock
The cabinet includes three doors. The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock.
Feeder cable and other external cables all use bottom wiring method.
The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.
Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
Door hinges use inner hinge mode.
Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.
2.6 Installation of Sensors
2.6.1 Door Sensor
2.6.2 Smoke Sensor
2.6.3 LED Lamp
3. Function
3.1 The cabinet uses galvanized steel and painted with outdoor powder, which is anti-corrosion, and anti-oxidant.
3.2 The cabinet uses 1500W AC air conditioner to maintain temperature inside it. The temperature can be automatically adjusted. When the ambient temperature is <45°C, temperature inside the compartment can be kept at 30°C.
3.3 The protection level of the cabinet is IP55,which can ensure the internal equipments are not affected by the outer environment.
4. Advantages
4.1 Protection level: IP55, the inside air is isolated with the outside air, to protect the power equipment from corrosion.
4.2 Both the cabinet and the air conditioner have high anti-corrosion performance, and high stability which can keep normal operation at outdoor environment.
4.3 Intelligent air conditioner: with cooling, heating intelligent temperature control; automatically adjust temperature; remote control.
4.4 Use anti-theft lock specially for outdoor application; support padlock.
5. Features
5.1 Cabinet material: galvanized steel + special outdoor powder, with 20mm heat insulation foam, including internal panel.
5.2 Temperature control: 1500W AC air conditioner; side installed.
5.3 Cabinet structure: integrated welded.
5.4 Cabinet doors: with 1 front door, 1 back door, and 1 left door.
5.5 Cabinet cable entry method: bottom entry.
5.6 Bottom air inlet; the air inlet uses 20mm dust proof cotton, which can be pulled; top cover air outlet.
Structure Diagram
6. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
7. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Website: www.estelecomcabinet.com
Contact Person: Fiona Liang
Tel: +8613752765943 / 86-0755 23592644