Send Message
Home ProductsBase Station Cabinet

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System

Certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
Customer Reviews
In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

The boxes are great we happy with it. We will order 30 sets each month in future. Cooperate Happily.

—— Andrej Sliachin

Always can provide us good suggestion and solution, we are very grateful.

—— Nelson

I'm Online Chat Now

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System
Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System

Large Image :  Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System

Product Details:
Place of Origin: Shenzhen, China (Mainland)
Brand Name: ESTEL
Certification: ISO9001, CE, 3C, FCC, TLC, IP55
Model Number: DDTE016
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: negotiation
Packaging Details: wooden case
Delivery Time: 10-15 working days
Payment Terms: L/C,D/A,T/T, Western Union, Paypal, etc
Supply Ability: 6,000 sets per month
Detailed Product Description
Model Number: DDTE016 Structure: Double Wall, With Insulation, Sandwich Structure.
Coating: Anti-corrosion Outdoor Powder Coating External Size: H×W×D 2100×1600×800mm
Applicaiton: Outdoor Telecom Base Station Protection: Dustproof, Sunproof And Rainproof
Highlight:

street cabinets telecoms

,

outdoor data cabinet

,

Base Station Cabinet Outdoor

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System

 

Quick Details

 

Place of Origin: Shenzhen, China (Mainland) External Size H×W×D 2100×1600×800mm
Brand Name: ESTEL Structure: sandwich structure, double wall, with insulation .
Model Number: DDTE016 Cabinet Layout: two compartments
Product Name: base station cabinet Cabinet Lock: anti-theft three point lock
Certification: ISO9001, CE, 3C, FCC, TLC, IP55 Protection Level: IP55
Application: outdoor telecom base station Cable Entry: at cabinet bottom
Material: galvanized steel Illumination: DC48V LED lamp
Heat Insulation: PEF Grounding Protection: copper bar
Color: grey (support custom made) Cooling: peltier air conditioner and heat exchanger
Coating: anti-corrosion outdoor powder coating Accessories Options: PDU, rectifier system, environment monitoring system

 

Payment & Shipping Terms

 

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: L/C,D/A,T/T, Western Union, Paypal, etc
Supply Ability: 6,000 sets per month
Delivery Time: 10-15 working days
Packaging Details: wooden case

 

1. Specifications

(1) Technical Parameters

 

Item Type Technical Parameter
Structure Dimension External Size H×W×D 2100×1600×800mm
Layout Two compartments
Equipment Installation Method 19” standard rack
Door With two front doors, and anti-theft three point lock for outdoor cabinet (support padlock)
Material

1.Galvanized steel;

2.Double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with 20mm heat insulation between two walls.

Structure Assembled
Ingress Protection IP55
Temperature Control Cooling peltier air conditioner and heat exchanger
Lighting LED lamp 48V LED lamp
Temperature Temperature Working Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
Humidity Relative Humidity 5% ~ 100%
Pressure Air Pressure 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation Intensity Solar Radiation Intensity 1124 × (1±5%)W/m2

 

Accessories List

 

No. Item Quantity Unit Specs
1 Two Compartments Outdoor Telecom Cabinet 1 Set External Dimension: H×W×D 2000×1600×800mm
2 Peltier Air Conditioner 1 Set

Cooling Capacity: 200W

Power Supply: DC48V

3 Heat Exchanger 1 Set

Heat Exchange Capacity: 80W/K

Power Supply: DC48V

4 Rectifier System 1 Set DC48V, 120A
5 Power Distribution Unit 1 Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4.

Height: 4U

6 Environment Monitoring Unit 1 Set  
7 Temperature and Humidity Sensor 2 PC  
8 Door Sensor 4 PC Two for controlling LED lamp on/off, the other two for door open alarm
9 Water Sensor 2 PC  
10 Smoke Sensor 2 PC  
11 LED Lamp 2 PC DC48V
12 Package 1 Set Wooden Case

 

 

2. Description

 

The DDTE016 Outdoor Integrated Telecom Enclosure is mainly used in wireless communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.

The cabinet, made of galvanized steel, is divided into equipment compartment and battery compartment. The right part of the cabinet is equipment compartment, which is separated from the battery compartment for heat insulation of the equipment space. The battery compartment is used for installing batteries. The cabinet body has heat insulation foam, which can keep the temperature inside the cabinet. The cabinet also has roofs which is sun proof and water proof. There’re ventilations for releasing harmful gas generated by the batteries.

The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock. There’s open door alarm sensor, which works together with the environment monitoring unit.

 

3. Features

 

  • The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment. The protection level is IP55.
  • Three cooling for the cabinet: heat exchanger ,air conditioner and fans-.
  • -48V lamp is installed inside the cabinet.
  • The cabinet is installed with Environment Monitoring Unit, door alarm, temperature and humidity sensor, smoke sensor, water sensor etc., which can work together to monitor the inside environment of the cabinet.
  • The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. There’re entrance holes individually for power cable, signal cable and optical cable.
  • All the cables used in the cabinet are made from flame retardant materials.

 

4. Cabinet Structure

4.1 Door and Door Limit

 

(1) Cabinet door options: vertical hinge door, horizontal hinge door.

(2) The door limit device can limit the door position when it is open.

(3) The door limit function is automatically activated when the door is open, and should be canceled manually when the door is closed

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 0

 

When the door is fully opened, the largest open angle is larger than 95°. If it is horizontal hinge door, it can prevent outside water from flowing into the equipment compartment from the upper side. The bottom edge of the door limit device is higher than the hinge level, which can offer enough operating space.

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 1

(5) After 1000 times open and close operation, the door and door device will have good function and have no excessive wear and tear.

(6) At the door limit status, the door limit device can bear the static load by door opening and closing at 22m/s wind, without mechanical failure and function failure.

 

4.2 Grounding

 

The cabinet include grounding copper bar, 4mm thick, with 10×M6 flare-in nuts, 2×M8 flare-in nuts, 2×M10 flare-in nuts. The grounding bar is nickel plated. The screw is made from copper bar and with passivation surface treatment.

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 2

 

4.3 Theft Proof Design

  • Theft proof lock

 

 Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 3

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 4Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 5

  • Three point lock

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 6

 

4.4 Cable Entry

 

Feeder cable and other external cables all use bottom wiring method.

 

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 7

 

4.5 Appearance and Surface Treatment

 

Outdoor powder coat, with gray color. The coat is anti-shock, anti-aging, anti-solvent, anti-low temperature.

 

5. Electrical Technical Parameters

5.1 Monitoring System Diagram and Solution

 

Monitoring alarm

 

The monitoring unit conducts real time monitoring on smoke, water, door opening, LED lamp, temperature and humidity inside each compartment through various sensors. It is with alarm output, and can transmit alarm signals to Local Area Network or remote monitoring platform through RS485/RS232, Ethernet etc.

 

Monitoring Unit Diagram

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 8

 

The monitoring unit uses dual core processing. the power supply uses DC/DC module. The measuring channel, power supply, and communication interfaces are electrically isolated, so the monitoring unit has high reliability . The MCU control design has functions of self management and self correction. The monitoring unit support RS485/RS232 communication method. With the communication interfaces, it can realize many kinds of communication modes, such as point to point communication, point to multipoint communication, wireless remote communication, which can meet the need of various system networks.

 

5.2 Monitoring and Alarm

 

The monitoring unit conducts the following monitoring and alarm for the cabinet: door alarm, power failure alarm, smoke alarm, water alarm, temperature and humidity detection and alarm, shock and tilt alarm, etc.

 

 

Door alarm

 

There are two door switches. The one near the top of the cabinet is used for control the on/off of LED lamp, and the other one detects the opening and closing of the cabinet door. When the door is open, the door switch closes, and the monitoring unit will transmit the alarm to the control center through RS485/RS232. Meanwhile, there is correlative alarm dry contact output (port AL6, AL7). It will close in abnormal situation.

 

 

Power failure alarm

 

The port “AC220V” on the monitoring unit is for utility power detecting input. In case of utility power failure, the monitoring unit will transmit the alarm signal to the control center through RS485/RS232, and there is correlative alarm dry contact output (port AL8, AL9). It will close in abnormal situation.

 

 

Smoke alarm

 

The port “S” on the monitoring unit is for smoke sensor detecting input. When smoke is detected, the red light on the smoke sensor turn bright, the monitoring unit will transmit the alarm to the control center, and there is correlative alarm dry contact output (port AL2, AL3). It will close in abnormal situation.

 

Water alarm

 

The port “w+. w-” on the monitoring unit is for water sensor detecting input. When water is detected inside the cabinet, the monitoring unit will transmit the alarm to the control center, and there is correlative alarm dry contact output (port AL4, AL5). It will close in abnormal situation.

 

Temperature and humidity detection and alarm

 

The port “5V, T1, H1, GND” on the monitoring unit is for temperature and humidity sensor of battery compartment detecting input, and port “5V, T2(or T3), H2(or H3), GND” is for temperature and humidity sensor of equipment compartment detecting input. The monitoring unit can conduct real time detecting on temperature and humidity inside the compartment. When temperature and humidity sensor send out alarm signal, the monitoring unit will transmit the alarm signal to the control center, and there is correlative alarm dry contact output (port AL0, AL1). It will close in abnormal situation.

 

 

 

5.3 Technical Parameters of Monitoring Unit and Sensors

Environment Monitoring Unit

 

  • 19”, 1U, power supply DC48V/AC220V
  • Communication mode: RS232/RS485
  • 8 analog inputs. 4 specially for temperature and humidity detecting, the other 4 for general analog detecting, universal input.
  • 13 switch DI inputs, the port function can be redefined through programing.
  • 14 switch DO outputs, the port function can be redefined through programing.
  • LCD display, user friendly

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 9

 

 

Door Alarm

 

(1) Technical Parameters:

Contact power: ≤10W

Voltage: ≤28VDC

Current: ≤0.5A

Contact impedance: ≤300mΩ

Action distance: 35mm

Fixing mode: embedded

Safety standard(UL):94-HB

 

 

Function:

When forcible entry (forcible opening the cabinet door) happens, the door sensor will send the door alarm signal, and transmit the alarm signal to the monitoring center in switching mode.

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 10

 

Power Failure Alarm

 

 

Technical Parameters:

Coil voltage: AC220V

Power: ≤0.1W

 

Working temperature: -20°C ~ 70°C

Working humidity: 0% ~ 95%

Communication mode: contact output

 

(2) Function:

When AC power supply failure happens, the sensor will send AC power supply failure alarm signal, and transmit the alarm signal to the monitoring center in switching mode.

 

Smoke Sensor

 

Technical Parameters:

Voltage: 5-24 VDC

Power: ≤1W

Working temperature: -20°C ~ 70°C

Working humidity: 0% ~ 95%

Communication mode: contact output

 

Function:

When burning or smoke happens inside the cabinet, the sensor will send out alarm signal, and transmit the alarm signal to the monitoring center in switching mode.

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 11

 

Water Sensor

 

(1) Technical Parameters:

Voltage: 5-15 VDC

Power: ≤0.5W

Alarming water level: 5mm

Working temperature: -20°C ~ 70°C

Working humidity: 0% ~ 95%

Communication mode: contact output

 

 

Function:

When water level inside the cabinet reach the alarming level, the sensor will send out alarm signal, and transmit the alarm signal to the monitoring center in switching mode.

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 12

 

Temperature Sensor

 

(1) Technical Parameters:

Voltage: +5VDC

Power: <0.5W

Temperature error: ±0.2°C

Temperature resolution: 0.0625°C

Working temperature: -50°C ~ 120°C

Working humidity: 0% ~ 95%

Communication mode: monobus

 

(2) Function:

When temperature inside the cabinet exceed the set range, the sensor will send out high temperature or low temperature alarm signal, and transmit the alarm signal to the monitoring center in switching mode.

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 13

 

Temperature Control Failure Alarm

 

(1) Technical Parameters:

Voltage: +5VDC

Power: <0.5W

Temperature error: ±0.5°C

Temperature resolution: 0.0625°C

Working temperature: -50°C ~ 120°C

Working humidity: 0% ~ 95%

Communication mode: monobus

 

(2) Function:

When temperature control device fails, the sensor will send out temperature control device failure alarm signal, and transmit the alarm signal to the monitoring center in switching mode.

 

6. Protection

 

The cabinet is corrosion proof, water proof, dust proof, condensation proof, wind proof, lightening proof. The protection level is IP55.

 

7. Lighting and other specs

 

(1) The working voltage of the lamp is -48VDC or 220VAC.

(2) LED lamp can turn on or turn off intelligently. When the cabinet door is open, the LED will turn on automatically. When the cabinet door is closed, the LED will turn off automatically.

Displacement sensor for detecting cabinet door. When the door is open, it pops up and at close circuit situation.

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 14

 

(3) The cabinet includes 220V power socket.

(4) The MDF compartment and equipment compartment have document holders.

(5) The service life of the cabinet sealing strip is longer than 10 years, and is easy for replacement.

 

8. Packing and Shipping

 

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System 15

 

Our Delivery Agent

 

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

 

9. Our Contact Information

 

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

           lxf.estel@hotmail.com
Skype: fiona.liang10

Contact Details
Tianjin Estel Electronic Science and Technology Co.,Ltd

Contact Person: Fiona Liang

Tel: +8613752765943 / 86-0755 23592644

Send your inquiry directly to us (0 / 3000)