Product Details:
Payment & Shipping Terms:
|
Material: | Hot Dip Galvanized Steel | Cable Gland: | At Cabinet Bottom |
---|---|---|---|
External Size: | 1600×1300×700(W×H×D) | Working Temperature: | -40°C ~ +55°C |
Heat Insulation: | PEF | Lock: | Anti-theft Three Point |
High Light: | BTS outdoor cabinet,outdoor data cabinet,Two Front Doors BTS Cabinet |
Two Front Doors Outdoor Rack Enclosure BTS Cabinet With Mixed Working Fluid Heat Exchanger
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | External size: 1600×1300×700(W×H×D) |
Brand Name: ESTEL | Structure: double wall, with insulation, sandwich structure. |
Model Number: DDTE013 | Cabinet Layout: two compartments |
Product Name:Outdoor Telecom Base Staition Cabinet | Cabinet Lock: anti-theft three point lock |
Certification: ISO9001, CE, 3C, FCC, TLC, IP55 |
Protection Level: IP55 |
Application: outdoor telecom base station | Cable Entry: at cabinet bottom |
Material: galvanized steel | Illumination: DC48V LED lamp |
Heat Insulation: PEF |
Grounding Protection: copper bar |
Color: grey (support custom made) |
Cooling:Optional(including DC48V fans, AC220V/DC48V air conditioner, DC48V heat exchanger, DC48V peltier air conditioner) |
Coating: anti-corrosion outdoor powder coating |
Accessories Options: environment monitoring system |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, Paypal, etc |
Supply Ability: | 6,300 sets per month |
Delivery Time: | 10-20 working days |
Packaging Details: | wooden case |
1.Specifications
(1) Technical Parameters
Item | Type | Technical Parameter |
Structure | Dimension | External size: 1600×1300×700mm (W×H×D) |
Layout | Two compartments | |
Equipment Installation Method | Battery shelf | |
Door |
With two front doors with anti-theft three point lock for outdoor cabinet (support padlock) |
|
Material |
1.Galvanized steel; 2.Double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls. |
|
Structure | Assembled | |
Ingress Protection | IP55 | |
Temperature Control | Cooling | Optional(including DC48V fans, AC220V/DC48V air conditioner, DC48Vheat exchanger, DC48V peltier air conditioner) |
Lighting | LED lamp | 48V LED lamp |
Temperature | Temperature | Working Temperature: -40°C ~ +55°C |
Storage Temperature: -50°C ~ + 70°C | ||
Transport Temperature: -50°C ~ +70°C | ||
Humidity | Relative Humidity | 5% ~ 100% |
Pressure | Air Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity | Solar Radiation Intensity | 1124 × (1±5%)W/m2 |
(2) Accessories List
No. | Item | Quantity | Unit | Specs |
1 | Two Compartment Outdoor Battery Cabinet | 1 | Set | External size: 1600×1300×700mm (W×H×D) |
2 | Cooling System | 2 | Set |
Options: including DC48V fans, AC220V/DC48V air conditioner, DC48Vheat exchanger, DC48V peltier air conditioner |
3 | Fan | 4 | Set | DC48V, START WORK AT 35°C |
4 | Environment Monitoring Unit | 1 | Set | SM2400,1U |
5 | Temperature and Humidity Sensor | 2 | PC | |
6 | Door Sensor | 4 | PC | DC48V,two for controlling LED Lamp,two for open door alarm |
7 | Water Sensor | 2 | PC | |
8 | Smoke Sensor | 2 | PC | |
9 | LED Lamp | 2 | PC | DC48V |
10 | Package | 1 | Set | Wooden Case |
2. Description
The outdoor thermostatic battery cabinet is designed to separate the battery working environment in base stations, and to create an individual thermostatic environment for batteries so as to increase the working temperature inside the base station, which is aimed at reducing power consumption and saving cost.
The outdoor battery cabinet is made up of three parts: the thermostatic cabinet, air conditioner, and controller. The thermostatic cabinet with the function of seal and insulation, which is used for installing batteries, has ventilation for exhausting hydrogen generated by batteries. The air conditioner uses compressor cooling to adjust temperature inside the cabinet. The controller individually controls the temperature of the battery cabinet, to make sure the thermostatic working environment for the batteries so as to ensure the service life of the batteries, and increase the temperature of main equipments and power equipments in the base station so as to reduce power consumption.
3. Technical specs
1). Environment:
Storage temperature: -40°C-- 70°C
Working temperature: -30°C-- 50°C
Storage humidity: ≤95%
Working humidity: ≤90%
Allowed altitude: 4000m
2). Power supply:
Two options:
3). Power:
(1) Controller power: ≤5W
(2) Air conditioner power:
Max operating power consumption: 200W;
Long running power consumption: ≤80W
4). External size: 1600×1300×700 (W×H×D)
5). The cabinet has two doors, convenient for batteries maintenance
6). Integrated heat transfer coefficient: ≤0.2W/(m2.K)
4. Features
1) The temperature inside the thermostatic cabinet can be controlled at the range: 15°C-- 25°C.
2) Through the air conditioner controller, the thermostatic cabinet controller can control and adjust the air conditioner temperature inside the equipment room, and increase the working temperature inside the equipment room to 30°C-- 40°C(the temperature is adjustable).
3) The cabinet can hold 24 2V batteries. (custom made)
4) The cabinet is installed with hydrogen exhaust and ventilation system, which can exhaust hydrogen at time set by the controller, and realize exchange of inside cabinet air and outside cabinet air.
5) The cabinet, with perfect air distribution design, can ensure the temperature of each battery inside the cabinet is constant and consistent.
6) The cabinet is equipped with failure alarm, When system equipment failure is detected, the alarm will start and will be transmitted through the controller to the monitoring center.
7) The cabinet is equipped with open door alarm. When unauthorized person open the door, it will automatically report the alarm.
8) The cabinet has RS485 remote monitoring access port.
9) The cabinet is with good heat insulation function. There’re heat insulation layer installed on the top, bottom, side, front and back of the cabinet. The cable outlet hole has insulating bushing. The hydrogen exhaust circulation system is treated with special technology, which can ensure the seal and heat insulation function of the cabinet is not affected.
The cabinet includes two front doors. The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock.
Feeder cable and other external cables all use bottom wiring method.
Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.
6. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
7. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Contact Person: Fiona Liang
Tel: +8613752765943 / 86-0755 23592644