| Product Details: 
 Payment & Shipping Terms: 
 | 
| Cabinet Lock: | Anti-theft Three Point Lock(support Padlock) | Cooling System: | 500W Cooling Capacity Air Conditioner And Two Fans. | 
|---|---|---|---|
| Protection Level: | IP55 | External Size: | 700mm×650mm×1300mm(H×W×D) | 
| Material: | 1.2mm Thick Galvanized Steel, Single Wall, With 20mm PEF Heat Insulation | Package: | Wooden Case With Pallets | 
| Cabinet: | Outdoor Telecom Cabinet | ||
| Highlight: | telecom equipment cabinet,outdoor telecom enclosure,Two Access Doors Telecom Cabinet | ||
19” Mounting Rack Air Conditioner Cooling System Outdoor Telecom Cabinet With Two Access Doors
1. Cabinet Accessaries List
| No. | Item | Quantity | Unit | Specs | 
| 1 | Outdoor Telecom Cabinet | 1 | Set | (1) External Dimension H×W×D 1300× 700× 650mm. (2) One compartment: including 24U 19” rack. (3) With one front door and one back door, with three point lock for outdoor cabinet. (4) Material: galvanized steel, single wall with thermal insulation. | 
| 2 | Air Conditioner | 1 | Set | Cooling Capacity: 500W Power Supply: 220VAC, 50Hz | 
| 3 | Fan | 2 | Set | 48VDC | 
| 4 | LED Lamp Switch | 1 | PC | For controlling LED lamp on/off | 
| 5 | LED Lamp | 1 | PC | 220VAC | 
| 6 | Package | 1 | Set | Wooden Case | 
2. Cabinet Technical Parameters
| Item | Type | Technical Parameter | 
| Structure | Dimension | External Size H*W*D 1300*700*650mm | 
| Layout | One compartment, used for installing 19” equipment | |
| Equipment Installation Method | 19” rack | |
| Door | With one front door and one back door ,anti-theft three point lock for outdoor cabinet (support padlock) | |
| Material | Galvanized steel, single wall with thermal insulation | |
| Structure | Assembled | |
| Ingress Protection | IP55 | |
| Temperature Control | Cooling | Air conditioner and fan | 
| Lighting | LED lamp | 220VAC | 
| Temperature | Temperature | Working Temperature: -40°C ~ +55°C | 
| Storage Temperature: -50°C ~ + 70°C | ||
| Transport Temperature: -50°C ~ +70°C | ||
| Humidity | Relative Humidity | 5% ~ 100% | 
| Pressure | Air Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) | 
| Radiation Intensity | Solar Radiation Intensity | 1120 × (1±5%) W/m2 | 
3. Cabinet Drawing
External Dimension H×W×D 1300×700×650mm(19”, 24U)
4. Theft Proof Design
(1) Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.
(2) Three point lock
5. Connection and Fastening
(1) Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
(2) Door hinges use inner hinge mode.

6. Cooling Sysem