Product Summary
Weatherproof 40U Air Conditioner Type Outdoor Telecom Cabinet With Emerson Power Supply 1 Product description 1.1 Appearance After the cabinet is installed, as shown in Figure 1 and Figure 2 Figure 1 Figure 2 1.2 Cabinet configuration The outdoor integrated cabinet configuration of this project is ...

Product Details

Highlight:

outdoor communication cabinets

,

outdoor telecom enclosure

,

AC Type Outdoor Telecom Cabinet

Application: Outdoor Telecom Site
Protection: IP55
Material: Sanwich Structure Panel, Galvanized Steel, Double Wall With Heat Insulation
Finish: Anti-corrosion Powder Coating
Space: 40U 19" Rack
Cooling System: AC220V 60Hz 1500W Air Conditioner
EMS: -48VDC
AC And DC Power Distribution Unit: AC/DC PDU
Embedded Power Supply: Brand: Emerson
Color: RAL7035 Grey
Product Description

Weatherproof 40U Air Conditioner Type Outdoor Telecom Cabinet With Emerson Power Supply

 

1 Product description

 

1.1 Appearance

 

After the cabinet is installed, as shown in Figure 1 and Figure 2

 

        

Weatherproof 40U Air Conditioner Type Outdoor Telecom Cabinet With Emerson Power Supply 0    Weatherproof 40U Air Conditioner Type Outdoor Telecom Cabinet With Emerson Power Supply 1

 

          Figure 1                                                                                                          Figure 2

 

 

1.2 Cabinet configuration

The outdoor integrated cabinet configuration of this project is as follows:

 

Cabinet type Configuration Quantity Specifications
Main cabinet 19 inch standard rack 1 40U
Illumination 1 48V DC, LED light
Air conditioner 1 Input voltage: AC220V 60Hz, cooling capacity: 1500W
Emergency fan 2 48VDC, bottom plate air intake
Grounding copper bar 1 M6 bolts 10
Busbar 1 M6 bolts 10
AC and DC power distribution unit 1

AC input: 63A/2P*1;

AC output: 63A/2P*1;

DC input : 63A/1P *1;

DC output : 16A/1P*1;

DC output : 10A/1P*3;

DC output : 6A/1P*3

Circuit breaker brand: Schneider

Socket 1 8 -bit universal socket, 220V 16A
Embedded power supply 1

Model: NetSure211 C46

DC48V, 60A, 3U

distribution unit *1

20A rectifier module *3

monitoring module *1

Brand: Emerson

Environmental monitoring system 1

1* environment monitoring unit, 1U, SNMP communication;

1* smoke sensor;

1* water sensor;

1* temperature & humidity sensor;

1* tilt & shock combination sensor;

1* door sensor

power supply: DC48V

Base sealing plate 1 1 set containing 6, before and after one, two right and left

 

 

1.3 Cabinet size

The size of a single cabinet is shown in Figure 3 . External size: W×D×H 905×905×2107mm

 

Weatherproof 40U Air Conditioner Type Outdoor Telecom Cabinet With Emerson Power Supply 2

 

                                                        Figure 3

 

1.4 Cabinet material

 

Sanwich structure panel, galvanized steel, double wall with heat insulation

 

2 Cabinet installation

2.1 Unpacking

Outdoor integrated cabinets are generally packed in wooden cases. When disassembling the package, take care to avoid damage to the cabinet.

 

Weatherproof 40U Air Conditioner Type Outdoor Telecom Cabinet With Emerson Power Supply 3

2.2 Cabinet base

The size of the base of the cabinet and the fixing hole of the base expansion bolt are shown in Figure 4 .

Weatherproof 40U Air Conditioner Type Outdoor Telecom Cabinet With Emerson Power Supply 4

                                                           Figure 4

 

2.3 Cabinet fixing

( 1 ) According to the hole position map or the scribe template of the cabinet base, the base expansion bolt hole of the cabinet is punched with a hammer drill in advance, and the diameter of the hole is referenced to the size of the expansion bolt;

( 2 ) First, fix the leftmost or rightmost first cabinet with expansion bolts, place the remaining cabinets one by one, and finally fix the cabinets with the expansion bolts.

( 3 ) If you need to seal the base of the cabinet, use the base sealing plate (optional) to seal the notch and hole around the base. The mounting screws are the M5 stainless steel screws in the cabinet attachment (see Figure 5 ).

Note: If the cement foundation is not flat, it is recommended to use a gasket or spacer to level the base of the cabinet.

Weatherproof 40U Air Conditioner Type Outdoor Telecom Cabinet With Emerson Power Supply 5

                                                                        Figure 5

 

Note: When crossing the wire loop, first cut the cross with a utility knife. After the cable is connected, seal the remaining gap on the wire loop with the sealing glue attached to the cabinet.,As shown below;

 