Product Details:
Payment & Shipping Terms:
|
Material: | Galvanized Steel | External Dimension: | W*D*H 700*720*1400mm |
---|---|---|---|
Equipment Installation Method: | 19” Rack | Heat Insulation: | 20mm PEF |
Cooling: | Fan | Ingress Protection: | IP55 |
Highlight: | Powder Coating Outdoor Data Cabinet,IP55 Outdoor Data Cabinet,IP55 outdoor rack cabinet |
IP55 Power Coating Outdoor Data Cabinet 19" Mounting Rails With Door Stopper
1. Outdoor Electrical Cabinet Description
This outdoor cabinet is 1300mm High and 720mm Wide and 720mm Deep. Designed to meet the requirements of an exterior cabinet capable of mounting deeper 19″ equipment, with additional facilities for mounting electrical metering and power distribution equipment and backup batteries. You can choose to be double doors or single door.
· High performance Air conditioner unit for heat removal
· Door stopper to hold door open at service
· 19" mounting rails
· Come with plinth for mounting on the floor ground, with cable grommets for the cabling
· Available in colors, Grey or customized colors
Item | Type | Technical Parameter |
Structure | Dimension | External Dimension: W*D*H 700*720*1400mm |
Layout | 1 compartment | |
Equipment Installation Method | 19” rack | |
Door | With one front door, and three point lock for outdoor cabinet (support padlock) | |
Material | Galvanized steel, single wall with insulation | |
Heat Insulation | 20mm PEF | |
Ingress Protection | IP55 | |
Temperature Control | Cooling | fan |
Lighting | LED lamp | LED lamp |
Temperature | Temperature | Working Temperature: -40°C ~ +55°C |
Storage Temperature: -50°C ~ + 70°C | ||
Transport Temperature: -50°C ~ +70°C | ||
Humidity | Relative Humidity | 5% ~ 100% |
Pressure | Air Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity | Solar Radiation Intensity | 1120 × (1±5%) W/m2 |
4. Security
Each cabinet door is secured with a three point locking mechanism and security lock with internal hidden hinges on left hand side.
(1) The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
(2) The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
(3) Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.
6. Door and Door Lock
(1) Cabinet door options: vertical hinge door, horizontal hinge door.
(2) The door limit device can limit the door position when it is open.
(3) The door limit function is automatically activated when the door is open, and should be canceled manually when the door is closed.
7. Picture
Contact Person: Fiona Liang
Tel: +8613752765943 / 86-0755 23592644