Product Details:
Payment & Shipping Terms:
|
Cooling Method: | Heat Pipe, Passive Cooling | Input Voltage: | DC-48V±20% |
---|---|---|---|
Cooling Capacity L35/L35: | 180W/K(1800W) | Power Consumption L35/L35: | 210W/K |
IP Grade: | IP55 | Dimensions (Include Flange): | W×D×H: 550×245×1350mm |
Working Temperature: | -40-65℃ | Mounting Method: | Embedded |
Airflow: | 950m3/h | ||
High Light: | cabinet heat exchanger,electric heat exchanger |
DC48V 180W/K Heat Exchanger With Remote Control, LED Display, Dry Contact Alarm Output For Telecom Cabinet
* Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;
* Power supply voltage range;
* LED display, all the settings can changed at the field;
* Strict process control and international brand parts deployed to ensure high quality and product;
* Anti-theft design, without the protection cover.
* Dry contact alarm output, NO/NC optional;
ESTEL is provide temperature solutions for communi-cations, with the world’s advanced technology and
rapid development, Meet the increasingly stringent reli-ability requirements. Create a cool, dry and safe
envi-ronment for the operation of equipment and electrical;
The product is widely used in outdoor communication cabinets, electrical cabinets, industrial cabinets and
other occasions need heat dissipation.
Product Model | ET180EE | Unit |
Dimensions (Include flange) | W×D×H 550×245×1350 | mm |
Dimensions (Without flange) | W×D×H 500×245×1300 | mm |
Weight | 50 | kg |
Mounting method | Embedded | |
Application temperature | -40-70 | ℃ |
Working temperature | -40-65 | ℃ |
Input voltage | DC-48V±20% | |
Cooling capacity L35/L35 | 180 | W/K |
Heating | -- | W |
Power consumption L35/L35 | 210 | W/K |
Airflow | 950 | m3/h |
IP grade | IP55 | |
Fan | 2*R1G225 | |
Noise | 65 | dB (A) |
Surface treatment | Outdoor powder coating RAL7035 |
◊ In order to avoid short circuit of air duct, it is suggested to make effective iso-lation between inner air inlet and outlet.
P.S. This product is free of cover, cus-tomers don’t need to install additional cover.
1. If the customer needs to install a protective cover, in order to ensure enough circulation of air, the opening rate of the air inlet and outlet should be greater than 60%. It is very im-portant to prolong the unit life and reduce the maintenance frequency.
2. The air inlet and outlet of the protec-tive cover should prevent short circuit of air duct, so that the air-con can get the best cooling effect.
3. Due to the opening of the housing problems caused by the fault, not in the scope of the warranty.
Contact Person: Fiona Liang