Product Details:
Payment & Shipping Terms:
|
Protection: | IP55 | Equipment Installation: | Standard 19" Rack |
---|---|---|---|
Door: | One Front Door | Inner Space: | 42U |
Coating: | Anti Corrosion Powder Coating | Cooling: | Air Conditioner And Fan |
Power Distribution Unit: | AC/DC | Light: | -48VDC |
Environment Monitoring: | -48VDC, SNMP Communication | ||
Highlight: | telecom equipment cabinet,outdoor telecom enclosure |
Item | Type | Technical Parameter |
Structure | Dimension |
External Dimension H×W×D 2200×900×900mm; Internal Dimension H×W×D 1900×800×800mm. |
Layout | 1 compartment | |
Equipment Installation Method | 19” rack | |
Door | With one front door, and special anti-theft three point lock for outdoor cabinet (support padlock) | |
Material | Sandwich structure panel, galvanized steel, double wall, there is heat insulation between two walls. | |
Structure | Assembled | |
Ingress Protection | IP55 | |
Temperature Control | Cooling | AC220V air conditioner and DC48V fans |
Lighting | LED lamp | 48V LED lamps (immovable), with protective circuit breaker |
Temperature | Temperature | Working Temperature: -40°C ~ +55°C |
Storage Temperature: -50°C ~ + 70°C | ||
Transport Temperature: -50°C ~ +70°C | ||
Humidity | Relative Humidity | 5% ~ 100% |
Pressure | Air Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity | Solar Radiation Intensity |
1120 ×(1±5%)W/m2 |
No. | Item | Quantity | Unit | Specs |
1 | Outdoor Telecom Cabinet | 1 | Set |
(1) External Dimension H×W×D 2200×900×900mm; Internal Dimension H×W×D1900×800×800mm.(19”, 42U) (2) One compartment,including 19” equipment rack. (3) With one front door, and special anti-theft three point lock for outdoor cabinet (support padlock) (4) Sandwich structure panel, galvanized steel, double wall, there is heat insulation between two walls. |
2 | Air Conditioner | 1 | Set |
Power supply: AC220V, 50HZ Cooling capacity: 1500W |
3 | Auxiliary Direct Ventilation Fan | 2 | PC | DC48V |
4 | Environment Monitoring System | 1 | Set |
1× environment monitoring unit,19”, 1U; NEM-500,SNMP communication, AC220V 1× smoke sensor, 1× water sensor, 1× temperature&humidity sensor, 1× door sensor, 1× tilt&shock sensor. |
5 | Power Distribution Unit |
Grade B Lightning Proof AC Input: 63A/2P ×1; AC Output: 16A/1P×4; DC Output: 16A/1P×4. Height: 4U |
||
6 | LED Lamp Switch | 1 | PC | Used for controlling LED lamp on/off |
7 | LED Lamp | 1 | PC | DC48V |
8 | Package | 1 | Set | Wooden Case |
External Dimension H×W×D 2200×900×900mm
Internal Dimension H×W×D 1900×800×800mm.
The ET9090220-EQ Outdoor Telecom Equipment Cabinet is mainly used in wireless communication base station, such as communication/network integrated service, 4G system, access/transmission switching station, emergency communication/transmission, etc.
19” Outdoor Rack cabinets especially designed for outdoor use: thermo-insulated and self-cooling double wall for better protection of the electronics, servers, CCTV, telecommunications, voice,data, fibre-optics etc. Ideal for protecting electronic equipment against temperature change
4.1 The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.
4.2 The cabinet cooling uses air conditioner and fans.
4.3 Including -48VDC illumination lamp.
4.4 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are entrance holes individually for power cable, signal cable and optical cable.
4.5 All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.
4.6 The cabinet includes 19” standard installation rack.
4.7 Material: good quality galvanized steel
4.8 Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
4.9 Cabinet load bearing: ≥400kg
4.10 Ingress protection: IP55
4.11 Flame retardance: comply with GB5169.7 test A
4.12 Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.
4.13 Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).
4.14 Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
(1) The door limit device can limit the door position when it is open.
(2) The door limit function is automatically activated when the door is open, and should be canceled manually when the door is closed
7.1 Position of installation holes at cabinet base are as follows:
7.2 Users prefabricate concrete base.
7.3 Cabinet fixing
Method 1: Pre-embed 4pcs M10×150 anchor bolts on the concrete base. Distance between bolts are as that in diagram 1. Bolt exposed height is 40mm. Put the cabinet on the concrete base, align anchor bolts, then screw on nuts, and tighten them with wrench.
Method 2: the cabinet accessories are equipped with M10*120 expansion bolts, directly drilling according to the size of the diagram, put the cabinet on the concrete base. Align the installation holes, insert expansion bolts and tighten them.
7.4 According to site situation, put the cabinet on the concrete base with forklift, crane or manually, and fix it on the concrete base with bolts.
(1) Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
(2) Door hinges use inner hinge mode.inside installation,inside fixing, no outer screws and embedded cabinet door, these design can protect cabinet against the theft and water access. Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.