Product Details:
Payment & Shipping Terms:
|
Cabinet Layout: | One Bay For 19'' Equipment | Structure: | Sandwich Structure Panel, Double Wall With Heat Insulation |
---|---|---|---|
Coating: | Anti-corrosion Outdoor Powder Coating | Protection: | Dustproof, Sunproof And Rainproof |
Cooling System: | 1500W AC220V Air Conditioner+DC48V Fans | Material: | Galvanized Steel |
Size: | H×W×D 2100×900×900mm | Protection Level: | IP55 |
Lock: | Anti-theft Three Point Lock (support Padlock) | Grounding Protection: | Copper Bar |
Door: | One Front Door + One Back Door | IP Grade: | IP55 |
High Light: | outdoor communication cabinets,telecom equipment cabinet |
Anti Corrosion Powder Coated Thermostatic Outdoor Telecom Cabinet With Front and Rear Access
1. Cabinet drawing
2. Cabinet Applications
The cabinet is suitable for outdoor environment, such as road side, park, building roof, mountain area, flat ground, etc.
The cabinet can be installed with base station equipments, power supply equipments, batteries, temperature control equipments, transmission equipments and other equipments, or the cabinet can reserve installation space and heat exchange capacity for the above equipments, providing reliable mechanical and environmental protection for normal operation of the internal equipments.
The cabinet is mainly used in wireless communication base station, such as 4G, communication/network integrated service, access/transmission switching station, emergency communication/transmission
3. Cabinet Features
In a word, our Energy Saving Integrated Cabinet can provide complete solutions for outdoor working environment and safety management of telecom base station. As a base station, it can integrate the main equipments, system power supply, AC and DC power distribution, environment monitoring, batteries, lightning protection and grounding devices. As functional cabinet (battery cabinet, power supply cabinet, transmission cabinet etc.), it can help telecom carriers to realize easy station obtaining, energy saving, fast deployment.
4. Cabinet Advantages Introduction
5. Cabinet Specifications
(1) Technical Parameters
Item | Type | Technical Parameter |
Structure | Dimension |
External Dimension: W×D×H 900×900×2100mm Internal Dimension: W×D×H 800×800×1800mm |
Layout | 1 compartment | |
Equipment Installation Method | 19” rack | |
Door | With one front door and one back door, and anti-theft three point lock for outdoor cabinet (support padlock) | |
Material | Galvanized steel, sandwich structure panel, double wall with heat insulation | |
Heat Insulation | There are heat insulation between inner wall and outer wall. | |
Ingress Protection | IP55 | |
Temperature Control | Cooling | AC220V 50Hz air conditioner and DC48V fans |
Lightning Proof | Grade B lightning proof | Nominal: 60KA, Max.: 100KA |
Lighting | LED lamp | 48V LED lamps (immovable), with protective circuit breaker |
Temperature | Temperature | Working Temperature: -40°C ~ +55°C |
Storage Temperature: -50°C ~ + 70°C | ||
Transport Temperature: -50°C ~ +70°C | ||
Humidity | Relative Humidity | 5% ~ 100% |
Pressure | Air Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity | Solar Radiation Intensity | 1120 ×(1±5%)W/m2 |
(2) Configuration List
No. | Item | Quantity | Unit | Specs |
1 | Outdoor Telecom Cabinet | 1 | Set |
(1) External Dimension:W×D×H 900×900×2100mm Internal Dimension: W×D×H 800×800×1800mm (2) One compartment: equipment compartment (3)With one front door and one back door , and anti-theft three point lock for outdoor cabinet (support padlock) (4) Material: galvanized steel, sandwich structure panel, double wall with heat insulation (4.1) Cabinet left side, right side and back: sandwich structure panel, outer plate: 0.5mm galvanized steel, inner plate: 0.5mm galvanized steel, insulation: 45mm flame retarded EPS. (4.2) Cabinet door and base: outer plate: 1.5mm galvanized steel , inner plate: 0.8mm galvanized steel, insulation: 40mm PEF. (4.3) Cabinet roof: sandwich structure panel (outer plate: 0.5mm galvanized steel, inner plate: 0.5mm galvanized steel, insulation: 45mm flame retarded EPS. ) + 1.0mm galvanized steel. |
2 | Air Conditioner | 1 | Set |
Cooling capacity: 1500W, Power supply: AC220V, 50HZ, Model:TC06-150JFH/01 |
3 | Auxiliary Direct Ventilation Fans | 2 | PC | DC48V |
4 | Environment Monitoring Unit | 1 | Set |
19", 1U; Power Supply: DC48V Support RS485 and TCP/IP communication interface |
5 | Water Sensor | 1 | PC | |
6 | Smoke Sensor | 1 | PC | |
7 | Temperature and Humidity Sensor | 1 | PC | |
8 | Door Sensor | 2 | PC | One for controlling LED lamp, the other for open door alarm |
9 | LED Lamp | 1 | PC | DC48V |
10 | Power Distribution Unit | 1 | Set |
Grade B Lightning Proof AC Input: 63A/2P *1; AC Output: 16A/1P*4; DC Output: 16A/1P*4 Input Voltage: AC220V. |
11 | Package | 1 | Set | Wooden Case |
6. Cabinet Details Introduction
Feeder cable and other external cables all use bottom wiring method.
Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.
Three point lock
The cabinet use inside door hinges,inside installation,inside fixing, no outer screws and embedded cabinet door, these design can protect cabinet against the theft and water access. Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
The surface of cabinet is made of special outdoor anticorrosive powder coating, the color is grey.
7. Cabinet Pictures
8. Cabinet Wooden Case Packing
Contact Person: Fiona Liang