19 Inch Rack Mount Embedded DC Power System, LLVD and BLVD Load Distribution, Battery Breakers, Smart Controller for Telecom Base Stations

Basic Properties
Place of Origin: China
Brand Name: ESTEL
Certification: CE UL FCC
Trading Properties
Minimum Order Quantity: 1 SET
Price: USD300-USD1000
Payment Terms: T/T, Western Union
Supply Ability: 5000
Product Summary
19 Inch Rack Mount Embedded DC Power System, LLVD and BLVD Load Distribution, Battery Breakers, Smart Controller for Telecom Base Stations This 19-inch rack-mount embedded DC power system provides centralized rectification, multi-tier load disconnection, and battery bank protection for mission...

Product Details

Highlight:

19 inch rack mount DC power system

,

LLVD BLVD load distribution

,

telecom base station smart controller

Led: Yes
Rectifier System: 24kW
Output Voltage: 42–58 Vdc
Current: 400A
Output Capacity: 16kw+18kw(N+1 Redundancy)
Mppt Voltage Range: 120Vdc To 340Vdc
Battery Layer No: One
Dc Input Voltage: 300 VDC
Max Input Ac: 475 VAC
Total Output Power: 12kW (Max)
Warranty: 1 Year
Communication Port: LAN, RS485
Output Mode: 3-Phase,4-Wire+GND
Input Voltage Dc: 85 - 300 VDC
Rated Capacity: 1000VA
Product Description

19 Inch Rack Mount Embedded DC Power System, LLVD and BLVD Load Distribution, Battery Breakers, Smart Controller for Telecom Base Stations

 

 

This 19-inch rack-mount embedded DC power system provides centralized rectification, multi-tier load disconnection, and battery bank protection for mission-critical power infrastructure. Built with a front-serviceable steel enclosure and internal copper busbar distribution, the unit integrates dual Low Voltage Load Disconnect groups (LLVD1 and LLVD2), a Battery Low Voltage Disconnect section (BLVD), four battery circuit breakers (BAT1–BAT4), a multi-slot modular bay with integrated cooling fan assemblies, and a digital supervisory controller with LAN, USB/serial ports, and terminal blocks.

 

 

Application Scenarios

  • Telecommunications Networks:    4G/5G base stations, distributed telecom cabinets, transmission relay sites, and fiber access hubs.

  • Data Centers & Edge Facilities:    Network equipment racks, colocation power distribution bays, and edge computing rooms.

  • Industrial & Utility Infrastructure:   Substation DC distribution, rail signaling cabinets, and process control enclosures.

  • Hybrid & Backup Power Systems:    Telecom sites with multi-bank battery strings requiring tiered load shedding during grid outages.

 

Technical Parameters

  • Form Factor: 19-inch rack-mount embedded chassis with side mounting flanges and grounding stud

  • Load Distribution Groups: 15 total breaker positions across LLVD1 (F1–F4), BLVD (F5–F11), and LLVD2 (F12–F15) using TENGEN and Nader circuit breakers

  • Battery Protection: 4 dedicated battery breaker channels (BAT1–BAT4) equipped with Nader breakers

  • Modular & Cooling Layout: 6 lower module bays (2 rows by 3 columns) with 3 louvered fan/module units installed

  • Controller & I/O: Front supervisory unit with status LEDs, display screen, LAN port, local port, and multi-row signal/alarm terminal blocks

  • Internal Busbar & Wiring: Heavy-duty busbar assembly with threaded stud terminals and top-mounted input terminal block

 

Key Features

  • Tiered Load Shedding (LLVD1, BLVD, LLVD2):   Separates loads across distinct disconnection groups so priority equipment stays powered longer while non-essential circuits disconnect first.

  • Four-Bank Battery Isolation:     Individual BAT1–BAT4 breakers allow safe maintenance and fault isolation on each battery string.

  • High-Density Modular Bay:    Supports modular power/fan expansion in a compact rack footprint with front access for streamlined servicing.

  • Centralized Monitoring & Alarms:    Combines front-panel status indicators, network connectivity, and terminal block interfaces for system supervision and external alarm signaling.

 

Operation Guide

1. Mechanical Mounting & Grounding:   Fasten the chassis into a standard 19-inch rack and attach the protective earth conductor to the side grounding stud before wiring power circuits.

2. Breaker & Input Verification:    Confirm all LLVD1, BLVD, LLVD2, and BAT1–BAT4 breakers are in the OFF position, and verify input wiring matches the top electrical schematic.

3. Power & Load Termination:   Connect incoming power to the top terminal block and busbar points, wire battery strings to BAT1–BAT4, and connect DC loads to F1–F15.

4. Module & Fan Seating:    Ensure all rectifier/fan modules in the lower bays are seated securely and signal/alarm wires are fastened in the terminal blocks.

5. Energization & Setup:   Close the main power feed first, verify normal DC bus voltage and controller status, then close BAT1–BAT4 followed by F1–F15 while configuring disconnect thresholds and alarms via the controller.