Product Details:
Payment & Shipping Terms:
|
Model Number: | NEM-500 | Application: | Outdoor Telecom Cabinet |
---|---|---|---|
Analog Input: | Four Ways | Digital Input: | Eight Ways |
Communication Interface: | RS485, Ethernet, RS485/232 Multiplex | MTBF: | >50000 Hours |
Operating Voltage: | 85 VAC To 300 VAC , Or 20 VDC To 60 VDC | Monitored Sensors: | Door Sensor, Smoke Sensor, Water Sensor, Temperature And Humidity Sensor, Etc. |
Highlight: | environmental monitoring systems,environmental monitoring devices |
Remote Monitoring Environment / Security Monitoring System Support RS485 RS232
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | Communication Interface: RS485, Ethernet, RS485/232 multiplex |
Brand Name: ESTEL | Analog Input: four ways |
Model Number: NEM-500 | Digital Input: eight ways |
Product Name: Environment Monitoring System | Dry contact (relay) output:eight ways |
Certification: ISO9001, CE, 3C, FCC, TLC | Operating Voltage: 85 VAC~300 VAC, or 20 VDC~ 60 VDC |
Application: Outdoor Telecom Cabinet | Alarm Sensors: door sensor, smoke sensor, water sensor, temperature and humidity sensor, tilt & shock combination sensor |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union |
Supply Ability: | 20,000 sets per month |
Delivery Time: | 7-10 working days |
Packaging Details: | carton/wooden case |
1. Description
The NEM-500 is a small high-reliability environment monitoring unit developed to provide environment/device control and remote monitoring for communications base stations, integrated equipment rooms, and out-door cabinets.
The monitoring unit monitors important environmental factors such as temperature, humidity, smog, water penetration, access control, vibration/leaning, main distribution frame (MDF), and surge protection device (SPD). When any value collected by a sensor exceeds the preset threshold, an alarm is sent through the LCD, buzzer, or system log.
The monitoring unit also provides complete device detection functions, such as switch power status detection. Through a preserved custom interface (optional), the unit can be connected to another sensor in main contact point output type.
2. Product Appearance
Chassis dimensions (H x W x D) are 43.6 mm (1U) x 482.6 mm (19 inches) x 122 mm. Front cabling is adopted. The following shows the front panel of the chassis:
Note: The diagram is for reference only and the dimensions may be different from those of the real device. Note: In this document, transmitter, sensor, and integrated transmitter have the same meaning.
Interface specifications
1.)Power switch
It is used to power on/off the device.
2.)Power interface
This device can be powered by AC or DC power supply.
AC voltage range: 85 VAC to 300 VAC;
DC voltage range: 20 VDC to 60 VDC
3.)Liquid crystal display (LCD)
It displays sensor status data and parameter configuration pages.
4.)Buttons
They are used together with the LCD for menu page up/down and parameter settings.
UP: — Go to the previous page up (when viewing), or increase the parameter value (when setting);
DOWN: — Go to the next page up (when viewing), or decrease the parameter value (when setting);
OK: — Confirm the selection of a menu option (when viewing), or of a parameter value (when setting).
5.)LEDs
They show the operation and alarm status of the monitoring unit.
Power LED: — It indicates that the device is powered on and running;
Minor alarm: — It indicates a minor alarm;
Major alarm: — It indicates a major alarm.
6.)Sensor input interfaces
Four current-type analog input ports, with 12 VDC power ports connected to temperature, or temperature and humidity combination sensors;
Eight switch (dry contact) input ports, three of which with 12 VDC power ports connected to access control, smog detector, infrared detector, or SPD sensors;
8.)Dry contact (relay) output interfaces
Eight ports are available to send alarm signals to the upper-level alarm center, or to control the device’s startup/close-down.
You can customize alarm rules, and associate any alarm signal with a relay among O1 to O8. Ports O1 to O4 output switch signals;
Ports O5 to O8 control large-current devices such as fans and heaters.
9.)RS485/RS232/Ethernet interfaces
Four ports: A is an optional Ethernet port; B and C are fixed RS485 ports; D is an RS485/RS232 multiplex port that can be set to work in either RS485 or RS232 mode. Port A, D can be switch by the system automatically.
Ports A and D are used to connect the remote computer or alarm center device;
Ports B and C are used to connect other RS485-interface devices, such as the switch power, air conditioners, heat exchangers, and temperature and humidity sensors. (Note: Transparent data transmission and forwarding are supported. The complete monitoring functionality is to be developed based on standard communications protocols.)
Configuration and cabling diagram:
Specifications of the Environment Monitoring System
Model |
NEM-510 |
NEM-520 |
NEM-530 |
Analog input port (4 mA to 20 mA) |
4 |
4 |
4 |
Dry contact (Digital) input port |
8 |
8 |
8 |
AC voltage detection (single phase) |
/ |
1 |
1 |
DC voltage detection |
1 |
1 |
1 |
Dry contact (relay) output port |
8 |
8 |
8 |
RS485 interface (fixed) |
2 |
2 |
2 |
RS485/RS232 multiplex interface for uploading (Can switch between RS485/RS232) |
1, fixed to RS485 |
1, RS485/RS232 multiplex |
1, RS485/RS232 multiplex |
Ethernet |
1, optional |
1, optional |
1, optional |
Water detection sensor module |
Supported, optional |
Supported, optional |
Supported, optional |
Thermostat (Control fans) |
/ |
Supported, optional |
Supported, optional |
Thermostat (Control heater) |
/ |
Supported, optional |
Supported, optional |
AC power (220 V) supply |
Supported, optional |
Supported, optional |
Supported, optional |
DC power (48 V) supply |
Supported, optional |
Supported, optional |
Supported, optional |
Remote computer monitoring software |
√ |
√ |
√ |
Controllable heat exchanger |
/ |
/ |
Supported, optional |
Monitored air conditioner |
/ |
/ |
Supported, optional |
Monitored switching power |
/ |
/ |
Supported, optional |
Monitored Smart Air-Conditioning Remote Control |
/ |
/ |
Supported, optional |
3. Features
3.1 Front maintenance (front cabling): higher space utilization and easy maintenance
3.2 Combat structure: standard 1U/19-inch chassis for easy installation
3.3 Monitoring of cabinet switch power: The monitoring unit can be connected to the switch power for transparent data transmission and forwarding. The complete monitoring functionality is to be developed based on standard communications protocols.
3.4 Uploading over standard protocols: The monitoring unit uploads environment data to the monitoring background and receives remote system commands over specified protocols in main contact point or RS485/232/IP mode.
3.5 Complete monitoring functionality: The monitoring unit intelligently controls all environment devices in an equipment room, and automatically monitors environment parameters against the alarm thresholds from remote.
3.6 GUI-based host computer control software:
3.7 Various sensors supported: The monitoring unit can be connected to various analog-output sensors, switch-output sensors, and RS232, RS485 interface sensors.
3.8 Built-in common sensors for simplified cabling during monitoring system installation Optional built-in DC power failure sensor, AC power failure sensor, and water sensor
3.9 Flexible power supply mode: voltage range as 85 VAC to 300 VAC, or 20 VDC to 60 VDC
4. Product Specifications
Environment variables
No. | Variable | Specification | Description |
1 |
Temperature
/Humidity |
4 |
Four port supports 4 mA to 20 mA current-type sensor; The port supports 4 temperature sensor, or 2 temperature/humidity combination sensor. |
2 | Water detection | 2 |
Leaking and water penetration detection
One port has a built-in sensor and you only need to connect the outside of the chassis to the pole; The other external port is connected to the external water sensor
(Dry contact interface). |
3 | Access control | 1 | Door status (open/close) detection |
4 | Smoke | 1 | Smoke and fire detection |
5 | AC power failure alarm | 1 |
Single-phase AC voltage detection One sensor is built in and the AC power cable must be connected to the local detection terminal. |
6 | DC power failure alarm | 1 |
DC voltage detection One sensor is built in and the DC power cable must be connected to the local detection terminal. |
7 | SPD | 1 | SPD status detection (Dry contact interface) |
8 | MDF | 1 | MDF status detection |
9 | Switching power | 1 |
Switching power status detection (RS485 connection in standard configuration) Optional RS232 serial port connection (through RS485-RS232 |
No. | Variable | Specification | Description |
Converter) Transparent data transmission and forwarding are supported. The complete monitoring functionality is to be developed based on standard communications protocols. |
|||
10 | Custom | 2 |
One port is connected to the switching power failure sensor (Dry contact interface) by default; The other port is connected to a custom dry contact type sensor,
with 12 V power supply for external sensors. |
Output ports
No. | Variable | Specification | Description |
1 | Dry contact output | 8 |
Custom output signal type:
O1/O2/O3/O4 are small-current output ports; O5/O6/O7/O8 are large-current output ports, with relay contact capacity as 5 A 250 VAC and 5 A 30 VDC. |
Communication ports
Four ports are configured as follows:
No. | Interface Type | Specification | Description |
1 | RS485 | 2 |
It is connected to the RS485 port of an intelligent device. Transparent data transmission and forwarding are supported. The complete monitoring functionality is to be developed based on standard communications protocols. |
2 | Ethernet | 1 (optional) |
It is connected to a remote computer or alarm center over
TCP/IP. |
3 |
RS485/232
multiplex |
1 |
It is connected to a remote computer or alarm center.
The interface type is RS232 or RS485 (RS485 by default). |
Note: Items 2 and 3 cannot coexist.
5. Functions
The monitoring unit collects data of environment variables (such as temperature, humidity, smog) and device variables (such as switch power), passes the data for multipoint control unit (MCU) processing and analysis, and shows the equipment room status on the local liquid crystal display (LCD) or remote computer;
An alarm is sent when any value collected by a sensor exceeds the preset threshold;
Historical alarms can be queried.
Local users can press the front panel buttons to query and set parameters and data;
The monitoring unit communicates with the host computer through the Ethernet (IP)/RS232/RS485/main contact point interface, and the host computer can read all status data of the monitoring unit and modify system settings from remote.
The remote control software for the host computer is optional.
6. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
7. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
Contact Person: Fiona Liang
Tel: +8613752765943 / 86-0755 23592644