Send Message
Home ProductsOutdoor Telecom Cabinet

IP65 Outdoor Telecom Cabinet With Front And Rear Door

Certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
Customer Reviews
In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

The boxes are great we happy with it. We will order 30 sets each month in future. Cooperate Happily.

—— Andrej Sliachin

Always can provide us good suggestion and solution, we are very grateful.

—— Nelson

I'm Online Chat Now

IP65 Outdoor Telecom Cabinet With Front And Rear Door

IP65 Outdoor Telecom Cabinet With Front And Rear Door
IP65 Outdoor Telecom Cabinet With Front And Rear Door IP65 Outdoor Telecom Cabinet With Front And Rear Door IP65 Outdoor Telecom Cabinet With Front And Rear Door IP65 Outdoor Telecom Cabinet With Front And Rear Door IP65 Outdoor Telecom Cabinet With Front And Rear Door IP65 Outdoor Telecom Cabinet With Front And Rear Door

Large Image :  IP65 Outdoor Telecom Cabinet With Front And Rear Door

Product Details:
Place of Origin: Shenzhen, China (Mainland)
Brand Name: ESTEL
Certification: ISO9001, CE, 3C, FCC, TLC, IP55
Model Number: ET100100180B
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: wooden case
Delivery Time: 15-20 working days
Payment Terms: L/C,D/A,T/T, Western Union, Paypal, etc
Supply Ability: 7,200 sets per month
Detailed Product Description
Cable Entry: From Cabinet Bottom Material: Galvanized Steel
Cabinet Lock: Anti-theft Three Point Lock External Dimension: H×W×D 1800×1000×1000mm
Doors: Two Illumination: DC48V LED Lamp
Cooling: DC48V 500W Air Conditioner
High Light:

outdoor communication cabinets

,

telecom equipment cabinet

 

IP65 19” Outdoor Telecom Equipment Cabinet With DC48V Cooling System / Customized Metal Outdoor Telecom Cabinet

 

Quick Details

 

Place of Origin: Shenzhen, China (Mainland) External Size H×W×D 1800×1000×1000mm

Brand Name: ESTEL

Structure: double wall, with insulation, sandwich structure

Model Number: ET100100180B

Cabinet Layout: one compartment, for installing 19” equipment

Product Name: Outdoor Telecom Equipment Cabinet

Cabinet Lock: anti-theft three point lock
Certification: ISO9001, CE, 3C, FCC, TLC, IP55

Protection Level: IP65

Application: outdoor telecom base station Cable Entry: at cabinet bottom
Material: galvanized steel Illumination: DC48V LED lamp

Heat Insulation: PEF

Grounding Protection: copper bar

Color: grey (support custom made)

Cooling: DC48V 500W air conditioner

Coating: anti-corrosion outdoor powder coating

Accessories Options: PDU,environment monitoring system

 

Payment & Shipping Terms

 

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: L/C,D/A,T/T, Western Union, Paypal, etc
Supply Ability: 7,200 sets per month
Delivery Time: 15-20 working days
Packaging Details: wooden case


1. Specifications

 

(1) Technical Parameters

 

Item Type Technical Parameter
Structure Dimension External Dimension H×W×D 1800×1000×1000mm
Layout One compartment
Equipment Installation Method 19” standard rack
Door

With one front door and one back door, totally two doors;

with anti-theft three point lock for outdoor cabinet (support padlock)

Material

1.Galvanized steel;

2.double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.

Structure Assembled
Ingress Protection IP65
Temperature Control Cooling

DC48V 500W air conditioner

Lighting LED lamp 48V LED lamp
Temperature Temperature Working Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
Humidity Relative Humidity 5% ~99%
Pressure Air Pressure 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation Intensity Solar Radiation Intensity 1124 × (1±5%)W/m2

 

(2) Accessories List

 

No. Item Quantity Unit Specs
         
1 Outdoor Telecom Cabinet 1 Set

(1) External Size H×W×D 1800×1000×1000mm

(2) One compartment;

(3) With one front door and one back door, totally two doors; with anti-theft three point lock for outdoor cabinet (support padlock)

(4) Material: galvanized steel; double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.

2 Air Conditioner 2 Set

Power Supply: DC48V

Cooling Capacity:500W

Model: SAD105

3 Power Distribution Unit 1 Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4.

Height: 4U

4 Environment Monitoring System 1 Set

1× environment monitoring unit, with TCP/IP communication port;

1× water sensor;

1× smoke sensor;

1× temperature and humidity sensor;

2× door sensor

5 LED Lamp 1 Pc DC48V
6 Package 1 Set Wooden Case

 

2. Application Scope

 

The Outdoor Telecom Cabinet is mainly used in communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.

 

3. Cabinet Introduction

3.1 Cabinet Material

 

The cabinet is made of galvanized steel, with double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm. There are heat insulation between inner wall and outer wall. The insulation material is 40mm PEF, heat insulation coefficient: 0.035W/m·K. The cabinet is assembled type.

 

3.2 Cabinet Structure

 

The cabinet includes 19” equipment installation rack. The cabinet includes two air conditioners, one installed on front door and another installed on back door.

 

3.3 Cabinet Door and Lock

 

The cabinet includes one front door and one back door. The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock. Each cabinet door include open door sensor, working together with the environment monitoring unit.

 

4. Features

 

4.1 The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.

4.2 The cabinet cooling uses air conditioner.

4.3 Including -48VDC illumination LED lamp.

4.4 The cabinet includes power and environment monitoring unit, which can send power failure alarm, door open alarm, temperature and humidity alarm, smoke alarm, water alarm etc.

4.5 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are cable inlets separately for power cable, signal cable and optical cable.

4.6 All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.

4.7 The cabinet includes 19” standard installation rack.

 

5. Technical Specs

  •  Applicable environment conditions:

     Operating temperature: -40°C ~ + 55°C

     Storage temperature: -50°C ~ + 70°C

     Transport temperature: -50°C ~ + 70°C

     Relative humidity (RH): 5%~99%

     Air pressure: 62kPa ~ 101kPa (similar to 0m ~ 5000m altitude)

  • Material: good quality galvanized steel
  • Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
  • Cabinet load bearing: ≥600kg
  • Ingress protection: IP65
  • Flame retardance: comply with GB5169.7 test A
  • Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).
  • Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
  • Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.

 

Dimension Diagram

 

Cabinet External Dimension (W×D×H): 1000×1000×1800mm.

6. Components Installation

6.1 LED lamp, LED lamp sensor, smoke sensor, door sensor and temperature & humidity sensor are installed at the top of the cabinet.

 

IP65 Outdoor Telecom Cabinet With Front And Rear Door 0

 

 

6.2 Water sensor is installed at the bottom of the cabinet.

 

IP65 Outdoor Telecom Cabinet With Front And Rear Door 1

 

 

 

6.3 PDU and environment monitoring unit are installed on 19” rack.

 

IP65 Outdoor Telecom Cabinet With Front And Rear Door 2

 

 

6.4 The cabinet includes totally two air conditioners, one air conditioner installed on front door and the other installed on back door.

 

IP65 Outdoor Telecom Cabinet With Front And Rear Door 3

 

6.5 The cabinet includes rubber base plate, for installation on transport telecom tower trailer.

7. Cable Inlet

Feeder cable and other external cables all use bottom wiring method.

8. Grounding Protection

  • The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
  • The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
  • Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.

9. Theft Proof Design

9.1 Door lock theft proof design

  • Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.
  • Three point lock

 

IP65 Outdoor Telecom Cabinet With Front And Rear Door 4

 

 

9.2 Connection and Fastening

  • Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
  • Door hinges use inner hinge mode.

9.3 Appearance and Surface Treatment

 

Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.

10. Air Conditioner

(1) Compressor Air Conditioner.
Model: SAD105.
Power Supply: DC48V.
Cooling Capacity: 500W.
Quantity: 2 pcs air conditioners for each cabinet, one installed on front door and the other installed on rear door.

 

(2) Working Principle: the cabinet includes auto switching controller for the two air conditioners. Air conditioner 1 is main air conditioner, and air conditioner 2 is backup air conditioner. Air conditioner 1 will keep working if there is no failure and alarm; only in case air conditioner 1 send failure alarm, air conditioner 2 will start to work, and air conditioner 1 will stop working.

 

 

 

 

 

Contact Details
Tianjin Estel Electronic Science and Technology Co.,Ltd

Contact Person: Fiona Liang

Tel: +8613752765943 / 86-0755 23592644