42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure

Certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
Customer Reviews
In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

The boxes are great we happy with it. We will order 30 sets each month in future. Cooperate Happily.

—— Andrej Sliachin

Always can provide us good suggestion and solution, we are very grateful.

—— Nelson

I'm Online Chat Now

42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure

42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure
42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure 42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure 42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure 42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure

Large Image :  42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure

Product Details:
Place of Origin: China
Brand Name: ESTEL
Certification: ISO9001
Model Number: ET9090220-EQ
Payment & Shipping Terms:
Minimum Order Quantity: 1PC
Packaging Details: Wooden Case
Delivery Time: 20 woking days
Payment Terms: T/T, L/C, Western Union, MoneyGram, D/A, D/P
Supply Ability: 2000PCS per month
Detailed Product Description
Protection: IP55 Equipment Installation: Standard 19" Rack
Door: One Front Door Inner Space: 42U
Coating: Anti Corrosion Powder Coating Cooling: Air Conditioner And Fan
Power Distribution Unit: AC/DC Light: -48VDC
Environment Monitoring: -48VDC, SNMP Communication
High Light:

telecom equipment cabinet

,

outdoor telecom enclosure

 42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure

 

 

1.Telecom Cabinet Technical Parameters

 

Item Type Technical Parameter
Structure Dimension

External Dimension H×W×D 2200×900×900mm;

Internal Dimension H×W×D 1900×800×800mm.

Layout 1 compartment
Equipment Installation Method 19” rack
Door With one front door, and special anti-theft three point lock for outdoor cabinet (support padlock)
Material Sandwich structure panel, galvanized steel, double wall, there is heat insulation between two walls.
Structure Assembled
Ingress Protection IP55
Temperature Control Cooling AC220V air conditioner and DC48V fans
Lighting LED lamp 48V LED lamps (immovable), with protective circuit breaker
Temperature Temperature Working Temperature: -40°C ~ +55°C
    Storage Temperature: -50°C ~ + 70°C
    Transport Temperature: -50°C ~ +70°C
Humidity Relative Humidity 5% ~ 100%
Pressure Air Pressure 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation Intensity Solar Radiation Intensity

1120 ×(1±5%)W/m2

 

 

2. Cabinet Accessories List

 

No. Item Quantity Unit Specs
1 Outdoor Telecom Cabinet 1 Set

(1) External Dimension H×W×D 2200×900×900mm;

Internal Dimension H×W×D1900×800×800mm.(19”, 42U)

(2) One compartment,including 19” equipment rack.

(3) With one front door, and special anti-theft three point lock for outdoor cabinet (support padlock)

(4) Sandwich structure panel, galvanized steel, double wall, there is heat insulation between two walls.

2 Air Conditioner 1 Set

Power supply: AC220V, 50HZ

Cooling capacity: 1500W

3 Auxiliary Direct Ventilation Fan 2 PC DC48V
4 Environment Monitoring System 1 Set

1× environment monitoring unit,19”, 1U; NEM-500,SNMP communication, AC220V

1× smoke sensor,

1× water sensor,

1× temperature&humidity sensor,

1× door sensor,

1× tilt&shock sensor.

5 Power Distribution Unit    

Grade B Lightning Proof

AC Input: 63A/2P ×1;

AC Output: 16A/1P×4;

DC Output: 16A/1P×4.

Height: 4U

6 LED Lamp Switch 1 PC Used for controlling LED lamp on/off
7 LED Lamp 1 PC DC48V
8 Package 1 Set Wooden Case
 

 

3.Cabinet Drawing:

 

External Dimension H×W×D 2200×900×900mm

Internal Dimension H×W×D 1900×800×800mm.

42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure 0

4. Cabinet Applications:

 

The ET9090220-EQ Outdoor Telecom Equipment Cabinet is mainly used in wireless communication base station, such as communication/network integrated service, 4G system, access/transmission switching station, emergency communication/transmission, etc.

 

19” Outdoor Rack cabinets especially designed for outdoor use: thermo-insulated and self-cooling double wall for better protection of the electronics, servers, CCTV, telecommunications, voice,data, fibre-optics etc. Ideal for protecting electronic equipment against temperature change

 

5. Cabinet Features:

 

4.1 The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.

4.2 The cabinet cooling uses air conditioner and fans.

4.3 Including -48VDC illumination lamp.

4.4 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are entrance holes individually for power cable, signal cable and optical cable.

4.5 All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.

4.6 The cabinet includes 19” standard installation rack.

4.7 Material: good quality galvanized steel

4.8 Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.

4.9 Cabinet load bearing: ≥400kg

4.10 Ingress protection: IP55

4.11 Flame retardance: comply with GB5169.7 test A

4.12 Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.

4.13 Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).

4.14 Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.

 

6.  Telecom Cabinet Door Limit

(1) The door limit device can limit the door position when it is open.

(2) The door limit function is automatically activated when the door is open, and should be canceled manually when the door is closed

 

42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure 1

 

7. Cabinet Installation

7.1 Position of installation holes at cabinet base are as follows:

 

42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure 2

 

7.2 Users prefabricate concrete base.

7.3 Cabinet fixing

Method 1: Pre-embed 4pcs M10×150 anchor bolts on the concrete base. Distance between bolts are as that in diagram 1. Bolt exposed height is 40mm. Put the cabinet on the concrete base, align anchor bolts, then screw on nuts, and tighten them with wrench.

Method 2: the cabinet accessories are equipped with M10*120 expansion bolts, directly drilling according to the size of the diagram, put the cabinet on the concrete base. Align the installation holes, insert expansion bolts and tighten them.

7.4 According to site situation, put the cabinet on the concrete base with forklift, crane or manually, and fix it on the concrete base with bolts.

 

 

8. Cabinet Connection and Fastening:

(1) Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.

(2) Door hinges use inner hinge mode.inside installation,inside fixing, no outer screws and embedded cabinet door, these design can protect cabinet against the theft and water access. Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.

42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure 3

9. Wooden case package 

42U Air Conditioner Type Outdoor Telecom Cabinet / Double Wall Heat Insulated Communication Enclosure 4

 

 

 

 

  

Contact Details
Tianjin Estel Electronic Science and Technology Co.,Ltd

Contact Person: Fiona Liang

Tel: 86-13752765943 / 86-0755 23592644

Send your inquiry directly to us (0 / 3000)